Evidence map›Paper›PMID 31840295›Full record

ArticleMagnetic resonance in medicine2020

Accelerated spin-echo functional MRI using multisection excitation by simultaneous spin-echo interleaving (MESSI) with complex-encoded generalized slice dithered enhanced resolution (cgSlider) simultaneous multislice echo-planar imaging.

SoHyun Han, Congyu Liao, Mary Kate Manhard, Daniel Joseph Park, Berkin Bilgic, Merlin J Fair, Fuyixue Wang, Anna I Blazejewska, William A Grissom, Jonathan R Polimeni and 1 more

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Simultaneous pure TNeuroImage · 2021
    Article
  5. Layer-dependent functional connectivity methods.Progress in neurobiology · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

SoHyun HanAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.ORCID 0000-0002-1309-7628
Congyu LiaoAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.ORCID 0000-0003-2270-276X
Mary Kate ManhardAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.
Daniel Joseph ParkAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.
Berkin BilgicAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.ORCID 0000-0002-9080-7865
Merlin J FairAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.ORCID 0000-0002-9100-3105
Fuyixue WangAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.
Anna I BlazejewskaAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.
William A GrissomVanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, USA.ORCID 0000-0002-3289-1827
Jonathan R PolimeniAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.
Kawin SetsompopAthinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts.

Funding

MRI CORTICOGRAPHY: DEVELOPING NEXT GENERATION MICROSCALE HUMAN CORTEX MRI SCANNERU01EB025162 · NIBIB · UNIVERSITY OF CALIFORNIA BERKELEY · PI FEINBERG, DAVID ALAN, LIU, CHUNLEI · 2017 to 2021
$13.4M
Project 4P41EB015896 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI ROSEN, BRUCE R · 2012 to 2018
$9.8M
Next generation in-vivo diffusion imaging at submillimeter resolutionR01MH116173 · NIMH · STANFORD UNIVERSITY · PI Yogesh Rathi, Kawin Setsompop · 2018 to 2026
$6.2M
fMRI Technologies for Imaging at the Limit of Biological Spatiotemporal Resolution: Administrative SupplementR01EB019437 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI POLIMENI, JONATHAN RIZZO, SETSOMPOP, KAWIN · 2015 to 2024
$5.5M
Improving Human fMRI through Modeling and Imaging Microvascular Dynamics: Administrative SupplementR01MH111419 · NIMH · MASSACHUSETTS GENERAL HOSPITAL · PI POLIMENI, JONATHAN RIZZO · 2016 to 2020
$4.9M
Rapid MRI acquisition for pediatric low-grade gliomasR01EB020613 · NIBIB · STANFORD UNIVERSITY · PI SETSOMPOP, KAWIN · 2016 to 2019
$2.5M
A Storage Area Network for Structural and Functional Image AnalysisS10RR023401 · NCRR · MASSACHUSETTS GENERAL HOSPITAL · PI FISCHL, BRUCE · 2009 to 2009
$2.0M
SILICON GRAPHICS PRISM EXTREME 128P/1TBS10RR023043 · NCRR · MASSACHUSETTS GENERAL HOSPITAL · PI SORENSEN, ALMA GREGORY · 2006 to 2006
$1.5M
A 3.0 Tesla MRI System in a Neuroscience ICUS10RR019254 · NCRR · MASSACHUSETTS GENERAL HOSPITAL · PI SORENSEN, ALMA GREGORY · 2004 to 2004
$500k
Computeserver Structural &Functional Image AnalysisS10RR019307 · NCRR · MASSACHUSETTS GENERAL HOSPITAL · PI FISCHL, BRUCE · 2004 to 2004
$496k
NCRR NIH HHS S10 RR019254NCRR NIH HHS S10 RR019307NCRR NIH HHS S10 RR023043NCRR NIH HHS S10 RR023401NIBIB NIH HHS P41 EB015896NIBIB NIH HHS R01 EB019437NIBIB NIH HHS R01 EB020613NIBIB NIH HHS U01 EB025162NIMH NIH HHS R01 MH111419NIMH NIH HHS R01 MH116173
6 · The paper itself

Abstract

purposeSpin-echo functional MRI (SE-fMRI) has the potential to improve spatial specificity when compared with gradient-echo fMRI. However, high spatiotemporal resolution SE-fMRI with large slice-coverage is challenging as SE-fMRI requires a long echo time to generate blood oxygenation level-dependent (BOLD) contrast, leading to long repetition times. The aim of this work is to develop an acquisition method that enhances the slice-coverage of SE-fMRI at high spatiotemporal resolution. THEORY AND

methodsAn acquisition scheme was developed entitled multisection excitation by simultaneous spin-echo interleaving (MESSI) with complex-encoded generalized slice dithered enhanced resolution (cgSlider). MESSI uses the dead-time during the long echo time by interleaving the excitation and readout of 2 slices to enable 2× slice-acceleration, while cgSlider uses the stable temporal background phase in SE-fMRI to encode/decode 2 adjacent slices simultaneously with a "phase-constrained" reconstruction method. The proposed cgSlider-MESSI was also combined with simultaneous multislice (SMS) to achieve further slice-acceleration. This combined approach was used to achieve 1.5-mm isotropic whole-brain SE-fMRI with a temporal resolution of 1.5 s and was evaluated using sensory stimulation and breath-hold tasks at 3T.

resultsCompared with conventional SE-SMS, cgSlider-MESSI-SMS provides 4-fold increase in slice-coverage for the same repetition time, with comparable temporal signal-to-noise ratio. Corresponding fMRI activation from cgSlider-MESSI-SMS for both fMRI tasks were consistent with those from conventional SE-SMS. Overall, cgSlider-MESSI-SMS achieved a 32× encoding-acceleration by combining R

conclusionHigh-quality, high-resolution whole-brain SE-fMRI was acquired at a short repetition time using cgSlider-MESSI-SMS. This method should be beneficial for high spatiotemporal resolution SE-fMRI studies requiring whole-brain coverage.

Indexed as

Brain MappingEcho-Planar ImagingBrainImage Processing, Computer-AssistedMagnetic Resonance ImagingSignal-To-Noise Ratiofunctional imagingGSliderHadamard encodingslice interleavingspin echo

Identifiers

PMID31840295
PMCPMC7083698

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.