Evidence map›Paper›PMID 31839968›Full record

ArticleHealthcare technology letters2019

Selection of optimum frequency bands for detection of epileptiform patterns.

Piyush Swami, Manvir Bhatia, Manjari Tripathi, Poodipedi Sarat Chandra, Bijaya K Panigrahi, Tapan K Gandhi

Abstract read
In one paragraph

Article in Healthcare technology letters, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Piyush SwamiCentre for Biomedical Engineering, Indian Institute of Technology - Delhi, New Delhi 110 016, India.ORCID 0000-0001-5839-352X
Manvir BhatiaDepartment of Neurosciences, Fortis Escorts Hospital, New Delhi 110 025, India.
Manjari TripathiDepartment of Neurology, All India Institute of Medical Sciences, New Delhi 110 029, India.
Poodipedi Sarat ChandraDepartment of Neurosurgery, All India Institute of Medical Sciences, New Delhi 110 029, India.
Bijaya K PanigrahiDepartment of Electrical Engineering, Indian Institute of Technology - Delhi, New Delhi 110 016, India.
Tapan K GandhiDepartment of Electrical Engineering, Indian Institute of Technology - Delhi, New Delhi 110 016, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The significant research effort in the domain of epilepsy has been directed toward the development of an automated seizure detection system. In their usage of the electrophysiological recordings, most of the proposals thus far have followed the conventional practise of employing all frequency bands following signal decomposition as input features for a classifier. Although seemingly powerful, this approach may prove counterproductive since some frequency bins may not carry relevant information about seizure episodes and may, instead, add noise to the classification process thus degrading performance. A key thesis of the work described here is that the selection of frequency subsets may enhance seizure classification rates. Additionally, the authors explore whether a conservative selection of frequency bins can reduce the amount of training data needed for achieving good classification performance. They have found compelling evidence that using spectral components with <25 Hz frequency in scalp electroencephalograms can yield state-of-the-art classification accuracy while reducing training data requirements to just a tenth of those employed by current approaches.

Indexed as

automated seizure detection systemclassification performanceclassification processelectroencephalographyelectrophysiological recordingsepileptiform patternsfrequency binsmedical disordersmedical signal detectionmedical signal processingneurophysiologyoptimum frequency bandsscalp electroencephalogramsseizure classification ratesseizure episodessignal classificationsignal decompositionstate-of-the-art classification accuracy

Identifiers

PMID31839968
PMCPMC6849498

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.