ArticleMedical physics2020
Experimental investigation of neural network estimator and transfer learning techniques for K-edge spectral CT imaging.
Article in Medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 19 citations in OpenAlex.
- Photon-counting detector CT in cardiovascular imaging: technical advances, clinical applications, and future perspectives.The international journal of cardiovascular imaging · 2026Review
- Systematic Review on Learning-based Spectral CT.ArXiv · 2024Article
- A Novel and Reliable Pixel Response Correction Method (DAC-Shifting) for Spectral Photon-Counting CT Imaging.Tomography (Ann Arbor, Mich.) · 2024Article
- Systematic Review on Learning-based Spectral CT.IEEE transactions on radiation and plasma medical sciences · 2024Article
- Artificial intelligence system-based histogram analysis of computed tomography features to predict tumor invasiveness of ground-glass nodules.Quantitative imaging in medicine and surgery · 2023Article
- Addressing CT metal artifacts using photon-counting detectors and one-step spectral CT image reconstruction.Medical physics · 2022Article
- Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment.IEEE transactions on radiation and plasma medical sciences · 2021Article
- Experimental study of photon-counting CT neural network material decomposition under conditions of pulse pileup.Journal of medical imaging (Bellingham, Wash.) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
purposeSpectral computed tomography (CT) material decomposition algorithms require accurate physics-based models or empirically derived models. This study investigates a machine learning algorithm and transfer learning techniques for Spectral CT imaging of K-edge contrast agents using simulated and experimental measurements.
methodsA feed forward multilayer perceptron was implemented and trained on data acquired using a step wedge phantom containing acrylic, aluminum, and gadolinium materials. The neural network estimator was evaluated by scanning a rod phantom with varying dilutions of gadolinium oxide nanoparticles and by scanning a rat leg specimen with injected nanoparticles on a bench-top photon-counting computed tomography system. The algorithm decomposed each spectral projection measurement into path lengths of acrylic and aluminum and mass lengths of gadolinium. Each basis material sinogram was reconstructed into basis material images using filtered backprojection. Machine learning techniques of data standardization, transfer learning from aggregated pixel data, and transfer learning from simulations were investigated to improve image quality. The algorithm was compared to a previously published empirical method based on a linear approximation and calibration error look-up tables.
resultsThe combined transfer learning techniques did not improve quantification in the rod phantom and provided only a small qualitative improvement in ring artifacts. Transfer learning from aggregated pixel data and from simulations improved the qualitative image quality of the rat specimen, for which the calibration data were limited. Transfer learning from aggregated pixel data and simulations estimated 3.26, 6.26, and 12.45 mg/mL Gd concentrations compared to true 2.72, 5.44, and 10.88 mg/mL concentrations in the rod phantom. Additionally, the neural networks were able to separate the soft tissue, bone, and gadolinium nanoparticles of the ex vivo rat leg specimen into the different basis images.
conclusionsThe results demonstrate that empirical K-edge imaging from calibration measurements using machine learning and transfer learning is possible without explicit models of material attenuations, incident spectra, or the detector response.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.