Evidence map›Paper›PMID 31834772›Full record

ReviewAccounts of chemical research2020

Electrophysiology, Unplugged: Imaging Membrane Potential with Fluorescent Indicators.

Pei Liu, Evan W Miller

Open access · greenAbstract readReview
In one paragraph

Review in Accounts of chemical research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 59 papers.

0numbers the graph read from it
0cells of the map it votes in
59citing papers in PubMed
7.4field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

59 citing papers in PubMed, 122 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Flipper dendrimers.Chemical science · 2026
    Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Water-Soluble Molecular Wires for Membrane Potential Imaging.Angewandte Chemie (International ed. in English) · 2025
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. A red-emitting carborhodamine for monitoring and measuring membrane potential.Proceedings of the National Academy of Sciences of the United States of America · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Pei Liu
University of California, Berkeley · US

Funding

Interrogating Neuronal Membrane Potential Dynamics with Optical Voltage SensorsR01NS098088 · NINDS · UNIVERSITY OF CALIFORNIA BERKELEY · PI Evan Walker Miller · 2017 to 2026
$4.4M
New Chemical Tools for Exploring Cellular PhysiologyR35GM119855 · NIGMS · UNIVERSITY OF CALIFORNIA BERKELEY · PI MILLER, EVAN WALKER · 2016 to 2020
$1.3M
NIGMS NIH HHS R35 GM119855NINDS NIH HHS R01 NS098088
6 · The paper itself

Abstract

Membrane potential is a fundamental biophysical property maintained by every cell on earth. In specialized cells like neurons, rapid changes in membrane potential drive the release of chemical neurotransmitters. Coordinated, rapid changes in neuronal membrane potential across large numbers of interconnected neurons form the basis for all of human cognition, sensory perception, and memory. Despite the importance of this highly orchestrated and distributed activity, the traditional method for recording membrane potential is through the use of highly invasive single-cell electrodes that offer only a small glimpse of the total activity within a system. Fluorescent dyes that change their optical properties in response to changes in biological voltage have the potential to provide a powerful complement to traditional electrode-based methods of inquiry. Voltage-sensitive fluorescent indicators would allow the direct observation of membrane potential changes, significantly expanding our ability to monitor membrane potential dynamics in living systems. Toward this end, we have initiated a program to design, synthesize, and apply voltage-sensitive fluorophores that report on membrane potential dynamics with high sensitivity and speed. The basis for this optical voltage sensing is membrane potential-dependent photoinduced electron transfer (PeT). Voltage-sensitive fluorophores, or VoltageFluors, possess a fluorophore, a conjugated molecular wire, and an aniline donor. At resting potentials, in which the cell has a hyperpolarized or negative potential relative to the outside of the cell, PeT from the aniline donor is enhanced and fluorescence is diminished. At depolarized potentials, the membrane potential decreases the rate of PeT, allowing an increase in fluorescence. We show that a number of different fluorophores, molecular wires, and aniline donors can be employed to generate fast and sensitive VoltageFluor dyes. Multiple lines of evidence point to a PeT-based mechanism for voltage sensing, delivering fast response kinetics (∼25 ns), good sensitivity (>60% Δ

Indexed as

AnimalsFluorescent DyesHumansMembrane PotentialsMolecular StructureFluorescent Dyes

Identifiers

PMID31834772
PMCPMC7266091
OpenAlexW2996586116

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.