ArticleJournal of applied clinical medical physics2019
Development and validation of a comprehensive patient-specific quality assurance program for a novel stereotactic radiation delivery system for breast lesions.
Article in Journal of applied clinical medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- Verifying calculated dose to the breast in stereotactic radiotherapy: A practical phantom-based method.Journal of applied clinical medical physics · 2026Article
- A Prospective Trial of Single-Fraction Radiation to the Tumor Bed with a Novel Breast-Specific Stereotactic Radiation Therapy Device: The GammaPod.Advances in radiation oncology · 2024Article
- Radiotherapy of early-stage breast cancer.Precision radiation oncology · 2023Review
- Correlation of treatment time to target volume for GammaPod treatments: A simple second calculation.Journal of applied clinical medical physics · 2022Article
- Reproducibility of a novel, vacuum-assisted immobilization for breast stereotactic radiotherapy.Journal of applied clinical medical physics · 2021Article
- Workflow guide to delivering a safe breast treatment using a novel stereotactic radiation delivery system.Journal of radiosurgery and SBRT · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe GammaPod is a dedicated prone breast stereotactic radiosurgery (SRS) machine composed of 25 cobalt-60 sources which rotate around the breast to create highly conformal dose distributions for boosts, partial-breast irradiation, or neo-adjuvant SRS. We describe the development and validation of a patient-specific quality assurance (PSQA) system for the GammaPod.
methodsWe present two PSQA methods: measurement based and calculation based PSQA. The measurements are performed with a combination of absolute and relative dose measurements. Absolute dosimetry is performed in a single point using a 0.053-cc pinpoint ionization chamber in the center of a polymethylmethacrylate (PMMA) breast phantom and a water-filled breast cup. Relative dose distributions are verified with EBT3 film in the PMMA phantom. The calculation-based method verifies point doses with a novel semi-empirical independent-calculation software.
resultsThe average (± standard deviation) breast and target sizes were 1263 ± 335.3 cc and 66.9 ± 29.9 cc, respectively. All ion chamber measurements performed in water and the PMMA phantom agreed with the treatment planning system (TPS) within 2.7%, with average (max) difference of -1.3% (-1.9%) and -1.3% (-2.7%), respectively. Relative dose distributions measured by film showed an average gamma pass rate of 97.0 ± 3.2 when using a 3%/1 mm criteria. The lowest gamma analysis pass rate was 90.0%. The independent calculation software had average agreements (max) with the patient and QA plan calculation of 0.2% (2.2%) and -0.1% (2.0%), respectively.
conclusionWe successfully implemented the first GammaPod PSQA program. These results show that the GammaPod can be used to calculate and deliver the predicted dose precisely and accurately. For routine PSQA performed prior to treatments, the independent calculation is recommended as it verifies the accuracy of the planned dose without increasing the risk of losing vacuum due to prolonged waiting times.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials