Evidence map›Paper›PMID 31832931›Full record

ArticleAnnals of biomedical engineering2020

The Feasibility of Using a Smartphone Magnetometer for Assisting Needle Placement.

Zhuo Zhao, Sheng Xu, Bradford J Wood, Hongliang Ren, Zion Tsz Ho Tse

Abstract read
In one paragraph

Article in Annals of biomedical engineering, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Zhuo ZhaoSchool of Electrical and Computer Engineering, University of Georgia, Athens, GA, USA.
Sheng XuCenter for Interventional Oncology, National Institutes of Health, Bethesda, MD, USA.
Bradford J WoodCenter for Interventional Oncology, National Institutes of Health, Bethesda, MD, USA.
Hongliang RenDepartment of Biomedical Engineering, National University of Singapore, Singapore, Singapore.
Zion Tsz Ho TseSchool of Electrical and Computer Engineering, University of Georgia, Athens, GA, USA. ziontse@uga.edu.ORCID http://orcid.org/0000-0001-9741-1137

Funding

Atlanta Clinical and Translational Science Institute (ACTSI) RenewalUL1TR000454 · NCATS · EMORY UNIVERSITY · PI STEPHENS, DAVID S · 2012 to 2016
$25.8M
Center for Interventional OncologyZIDBC011242 · NCI · DIVISION OF BASIC SCIENCES - NCI · PI WOOD, BRADFORD J · 2009 to 2025
$18.7M
Development of COVID-19 Imaging Tools with Artificial IntelligenceZIABC011936 · NCI · DIVISION OF BASIC SCIENCES - NCI · PI WOOD, BRADFORD J · 2020 to 2025
$1.2M
Navigation Tools for Image Guided Minimally invasive TherapiesZIACL040011 · CLC · CLINICAL CENTER · PI WOOD, BRADFORD · 2009 to 2025
$0k
Interventional OncologyZIACL040015 · CLC · CLINICAL CENTER · PI WOOD, BRADFORD · 2009 to 2025
$0k
American Society for Quality Dr. Richard J. Schlesinger GrantClinical and Translational Science PHS Grant UL1TR000454Foundation for the National Institutes of Health BC011242 & CL040015Foundation for the National Institutes of Health Interventional Oncology GrantIntramural NIH HHS ZIA BC011936Intramural NIH HHS ZIA CL040015Intramural NIH HHS ZID BC011242National Science Foundation I-Corps Team Grant (1617340)National Science Foundation REU site program 1359095NCATS NIH HHS UL1 TR000454NIH HHS Bench-to-Bedside AwardUniversity of Georgia Inter-Institutional Seed Funding
6 · The paper itself

Abstract

Minimally invasive surgical procedures often require needle insertion. For these procedures, efficacy greatly depends on precise needle placement. Many methods, such as optical tracking and electromagnetic tracking, have been applied to assist needle placement by tracking the real-time position information of the needle. Compared with the optical tracking method, electromagnetic tracking is more suitable for minimally invasive surgery since it has no requirement of line-of-sight. However, the devices needed for electromagnetic tracking are usually expensive, which will increase the cost of surgery. In this study, we presented a low-cost smartphone-based permanent magnet tracking method compatible with CT imaging and designed a 3D printed operation platform to assist with needle placement prior to needle insertion during minimally invasive surgery. The needle positioning accuracy of this method was tested in an open air test and a prostate phantom test in a CT environment. For these two tests, the average radial errors were 0.47 and 2.25 mm, respectively, and the standard deviations were 0.29 and 1.63, respectively. The materials and fabrication required for the presented method are inexpensive. Thus, many image-guided therapies may benefit from the presented method as a low-cost option for needle positioning prior to needle insertion.

Indexed as

NeedlesSmartphoneEquipment DesignFeasibility StudiesMagnetometryMinimally Invasive Surgical ProceduresPhantoms, ImagingPrinting, Three-DimensionalTomography, X-Ray ComputedMagnet trackingNeedle placementSmartphone

Identifiers

PMID31832931
PMCPMC8998157

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.