Magnetic resonance and ultrasound image-guided navigation system using a needle manipulator.

Atsushi Yamada, Junichi Tokuda, Shigeyuki Naka, Koichiro Murakami, Tohru Tani, Shigehiro Morikawa

Abstract read
In one paragraph

Article in Medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Robotic Assistance in Percutaneous Liver Ablation Therapies: A Systematic Review and Meta-Analysis.Annals of surgery open : perspectives of surgical history, education, and clinical approaches · 2024
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Atsushi YamadaDepartment of Research and Development for Innovative Medical Devices and Systems, Shiga University of Medical Science, Otsu, Shiga, 520-2192, Japan.
Junichi TokudaNational Center for Image Guided Therapy, Brigham and Women's Hospital and Harvard Medical School, Boston, MA, 02115, USA.
Shigeyuki NakaDepartment of Surgery, Shiga University of Medical Science, Otsu, Shiga, 520-2192, Japan.
Koichiro MurakamiDepartment of Surgery, Shiga University of Medical Science, Otsu, Shiga, 520-2192, Japan.
Tohru TaniDepartment of Research and Development for Innovative Medical Devices and Systems, Shiga University of Medical Science, Otsu, Shiga, 520-2192, Japan.
Shigehiro MorikawaMolecular Neuroscience Research Center, Shiga University of Medical Science, Otsu, Shiga, 520-2192, Japan.

Funding

Image Guided Therapy Center - Ultrasound-based sensor system for the monitoring of COVID-19 patientsP41EB015898 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI TEMPANY, CLARE M · 2012 to 2021
$18.9M
Open Software Platform for Data-Driven Image-Guided Robotic InterventionsR01EB020667 · NIBIB · BRIGHAM AND WOMEN'S HOSPITAL · PI DIAZ-MERCADO, YANCY, KRIEGER, AXEL · 2015 to 2024
$4.1M
JSPS KAKENHI 18H01408JSPS KAKENHI 26282145NIBIB NIH HHS P41 EB015898NIBIB NIH HHS R01 EB020667NIH HHS P41EB015898NIH HHS R01EB020667
6 · The paper itself

Abstract

purposeImage guidance is crucial for percutaneous tumor ablations, enabling accurate needle-like applicator placement into target tumors while avoiding tissues that are sensitive to injury and/or correcting needle deflection. Although ultrasound (US) is widely used for image guidance, magnetic resonance (MR) is preferable due to its superior soft tissue contrast. The objective of this study was to develop and evaluate an MR and US multi-modal image-guided navigation system with a needle manipulator to enable US-guided applicator placement during MR imaging (MRI)-guided percutaneous tumor ablation.

methodsThe MRI-compatible needle manipulator with US probe was installed adjacent to a 3 Tesla MRI scanner patient table. Coordinate systems for the MR image, patient table, manipulator, and US probe were all registered using an optical tracking sensor. The patient was initially scanned in the MRI scanner bore for planning and then moved outside the bore for treatment. Needle insertion was guided by real-time US imaging fused with the reformatted static MR image to enhance soft tissue contrast. Feasibility, targeting accuracy, and MR compatibility of the system were evaluated using a bovine liver and agar phantoms.

resultsTargeting error for 50 needle insertions was 1.6 ± 0.6 mm (mean ± standard deviation). The experiment confirmed that fused MR and US images provided real-time needle localization against static MR images with soft tissue contrast.

conclusionsThe proposed MR and US multi-modal image-guided navigation system using a needle manipulator enabled accurate needle insertion by taking advantage of static MR and real-time US images simultaneously. Real-time visualization helped determine needle depth, tissue monitoring surrounding the needle path, target organ shifts, and needle deviation from the path.

Indexed as

Magnetic Resonance ImagingNeedlesAblation TechniquesAnimalsCattleFeasibility StudiesImage-Guided BiopsyImage Processing, Computer-AssistedLiverPhantoms, ImagingUltrasonographyWorkflowimage-guided therapyliver ablationmagnetic resonance imagingmedical robot

Identifiers

PMID31829440
PMCPMC7067635

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.