ArticleGeneral thoracic and cardiovascular surgery2020
Long-term effects of pleural defect repair using sheet materials in a canine model.
Article in General thoracic and cardiovascular surgery, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 14 citations in OpenAlex.
- Alteration of PGA sheet composition improves histocompatibility and facilitates pleural repair.Surgery today · 2026Article
- Oxidized regenerated cellulose particles enable high-pressure air-leak sealing on lung segmentectomy surfaces in porcine models.Frontiers in bioengineering and biotechnology · 2026Article
- Isogenic Transplantation of Hybrid Artificial Pleural Tissue Consisting of Rat Cells and Polyglycolic Acid Nanofiber Sheet Induces Restoration of Mesothelial Defects in Rat Model.Artificial organs · 2025Article
- Comparison of early recurrence in young-onset primary spontaneous pneumothorax following surgery using different covering methods.General thoracic and cardiovascular surgery · 2025Article
- Physical pressure resistance of gastrointestinal anastomotic site via plate of polyglycolic acid promoting fibrosis.Scientific reports · 2024Article
- Article
- Novel external reinforcement device for gastrointestinal anastomosis in an experimental study.BMC surgery · 2023Article
- A combination of polyglycolic acid fabric and fibrin glue prevents air leakage from a lung defect.Interactive cardiovascular and thoracic surgery · 2022Article
- Efficacy of oxidized regenerated cellulose combined with fibrin glue in reducing pulmonary air leakage after segmentectomy in a porcine lung model.Frontiers in bioengineering and biotechnology · 2022Article
- Prevention of anastomotic leakage using a polyglycolic acid sheet in double-stapling technique anastomosis for rectal surgery.Annals of medicine and surgery (2012) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveA sheet material is widely used to repair pleural defects due to its excellent pressure resistance. We examined the long-term effects of sheet materials using an animal pleural defect model.
methodsBeagles were used for this study. The 5-mm circular pleural defects were created at 2 sites on each of the anterior, medial, and posterior lobe and repaired using a 2 cm square sheet material. The frequency of adhesion of those sheets to the thoracic walls and histological changes was examined after 6 months. In this study, three types of sheet materials were examined: polyglycolic acid, nano-polyglycolic acid, and oxidized regenerated cellulose where each sheet was tested with or without coating with fibrin glue, for a total of 6 groups. Each group contained an equal number of defect sites and evaluation of 12 defect sites was conducted.
resultsAdhesion was observed in 16 of 72 sites (22%). Presence or absence of adhesion was not affected by the repair method or by the type of sheet material used. However, the use of fibrin glue significantly reduced the occurrence of adhesion (p = 0.023). At the defected sites, the posterior lobe showed significantly less adhesion (p = 0.019). Histologically, the sheet materials caused a thickening of the pleural wall 6-10 times thicker than the normal pleural wall.
conclusionNo statistically significant differences regarding the presence or absence of adhesion to the thoracic wall were found among the sheet materials. The use of fibrin glue significantly reduced the adhesion to the thoracic wall.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.