Evidence map›Paper›PMID 31827155›Full record

ArticleScientific reports2019

Projection-to-Projection Translation for Hybrid X-ray and Magnetic Resonance Imaging.

Bernhard Stimpel, Christopher Syben, Tobias Würfl, Katharina Breininger, Philip Hoelter, Arnd Dörfler, Andreas Maier

Abstract read
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Bernhard StimpelPattern Recognition Lab, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany. bernhard.stimpel@fau.de.ORCID http://orcid.org/0000-0002-0573-9838
Christopher SybenPattern Recognition Lab, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.
Tobias WürflPattern Recognition Lab, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.
Katharina BreiningerPattern Recognition Lab, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.
Philip HoelterDepartment of Neuroradiology, University Hospital Erlangen, Erlangen, Germany.ORCID http://orcid.org/0000-0001-9768-9630
Arnd DörflerDepartment of Neuroradiology, University Hospital Erlangen, Erlangen, Germany.
Andreas MaierPattern Recognition Lab, Friedrich-Alexander University Erlangen-Nürnberg, Erlangen, Germany.ORCID http://orcid.org/0000-0002-9550-5284

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Hybrid X-ray and magnetic resonance (MR) imaging promises large potential in interventional medical imaging applications due to the broad variety of contrast of MRI combined with fast imaging of X-ray-based modalities. To fully utilize the potential of the vast amount of existing image enhancement techniques, the corresponding information from both modalities must be present in the same domain. For image-guided interventional procedures, X-ray fluoroscopy has proven to be the modality of choice. Synthesizing one modality from another in this case is an ill-posed problem due to ambiguous signal and overlapping structures in projective geometry. To take on these challenges, we present a learning-based solution to MR to X-ray projection-to-projection translation. We propose an image generator network that focuses on high representation capacity in higher resolution layers to allow for accurate synthesis of fine details in the projection images. Additionally, a weighting scheme in the loss computation that favors high-frequency structures is proposed to focus on the important details and contours in projection imaging. The proposed extensions prove valuable in generating X-ray projection images with natural appearance. Our approach achieves a deviation from the ground truth of only 6% and structural similarity measure of 0.913 ± 0.005. In particular the high frequency weighting assists in generating projection images with sharp appearance and reduces erroneously synthesized fine details.

Identifiers

PMID31827155
PMCPMC6906424

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.