Evidence map›Paper›PMID 31826168›Full record

ArticleRevista latino-americana de enfermagem2019

Use of pH reagent strips to verify gastric tube placement in newborns.

Flávia de Souza Barbosa Dias, Beatriz Pera de Almeida, Beatriz Regina Alvares, Rodrigo Menezes Jales, Jamil Pedro de Siqueira Caldas, Elenice Valentim Carmona

Open access · diamondAbstract read
In one paragraph

Article in Revista latino-americana de enfermagem, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.1field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Flávia de Souza Barbosa DiasAutonomous researcher, Valinhos, SP, Brazil.ORCID http://orcid.org/0000-0003-0191-9724
Beatriz Pera de AlmeidaUniversidade Estadual de Campinas, Hospital da Mulher Prof. Dr. José Aristodemo Pinotti, Campinas, SP, Brazil.ORCID http://orcid.org/0000-0002-3766-8165
Beatriz Regina AlvaresUniversidade Estadual de Campinas, Faculdade de Ciências Médicas, Campinas, SP, Brazil.ORCID http://orcid.org/0000-0002-0181-3885
Rodrigo Menezes JalesUniversidade Estadual de Campinas, Faculdade de Ciências Médicas, Campinas, SP, Brazil.ORCID http://orcid.org/0000-0002-8802-8870
Jamil Pedro de Siqueira CaldasUniversidade Estadual de Campinas, Faculdade de Ciências Médicas, Campinas, SP, Brazil.ORCID http://orcid.org/0000-0001-5292-2320
Elenice Valentim CarmonaUniversidade Estadual de Campinas, Faculdade de Enfermagem, Campinas, SP, Brazil.ORCID http://orcid.org/0000-0001-9976-3603
Universidade Estadual de Campinas (UNICAMP) · BRAgencia Regional da Energia e Ambiente da Regiao Autonoma da Madeira · PT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveto confirm the accuracy of the pH test in identifying the placement of the gastric tube in newborns.

methoddouble-blind, diagnostic test study conducted with 162 newborns admitted to a neonatal intensive care unit and an intermediate care unit. The subjects were submitted to enteral intubation, followed by pH test with reagent strip, which was analyzed by a nurse, and radiological examination, analyzed by radiologist. Blinding was kept among professionals regarding test results. Diagnostic accuracy analysis of the pH test in relation to the radiological exam was performed.

resultsthe sample consisted of 56.17% boys, with average birth weight of 1,886.79g (SD 743,41), 32.92 (SD 2.99) weeks of gestational age and the mean pH was 3.36 (SD 1.27). Considering the cutoff point of pH≤5.5, the sensitivity was 96.25%, specificity 50%, positive predictive value 99.35% and negative predictive value 14.29%.

conclusionThe pH test performed with reagent strips is sensitive to identify the correct placement of the gastric tube, so it can be used as an adjuvant technique in the evaluation of the gastric tube placement. In interpreting the results, pH ≤5.5 points to correct placement and values > 5.5 require radiological confirmation.

Indexed as

Reagent StripsDouble-Blind MethodFemaleGestational AgeHumansInfant, NewbornIntensive Care Units, NeonatalIntubation, GastrointestinalMalePostoperative ComplicationsSensitivity and SpecificityReagent Strips

Identifiers

PMID31826168
PMCPMC6896807
OpenAlexW2992150777

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.