ArticleJournal of intelligent material systems and structures2019
Design, Analysis, and Fabrication of a Piezoelectric Force Tray for Total Knee Replacements.
Article in Journal of intelligent material systems and structures, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 6 citations in OpenAlex.
- Detecting Condylar Lift-Off with a Piezoelectric Smart Knee Replacement.Bioengineering (Basel, Switzerland) · 2026Article
- Performance of a Piezoelectric Energy Harvesting System for an Energy-Autonomous Instrumented Total Hip Replacement: Experimental and Numerical Evaluation.Materials (Basel, Switzerland) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
Force plates have been widely adopted in biomechanical gait analysis to measure reaction forces and the center of pressure. In this work, the force plate concept is miniaturized and extended for use within the polyethylene bearing insert of a total knee replacement (TKR). A simplified rectangular-shaped force plate with multiple integrated piezoelectric sensors, including designs with six and eight transducers, is presented in this work. The performance of the sensory system is investigated through finite element analysis and experimental validation. Initially, the ability of the two designs in sensing compartmental forces and contact point locations on one side of the force plate is numerically investigated. Selected designs of the force plate are then fabricated and used to experimentally validate the performance of the system. The results show a maximum error of less than 6% and 4.5% in compartmental force amplitude sensing for the force plates with six and eight transducers, respectively. The force plates were able to detect the contact point location with maximum errors of less than 1 mm. The relatively small sensing error quantities show the potential of using a piezoelectric force plate sensor design in TKR as well as other force sensing applications.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.