Evidence map›Paper›PMID 31823831›Full record

ArticleActa veterinaria Scandinavica2019

Magnetic resonance imaging and computed tomography of equine cheek teeth and adjacent structures: comparative study of image quality in horses in vivo, post-mortem and frozen-thawed.

Christin Röttiger, Maren Hellige, Bernhard Ohnesorge, Astrid Bienert-Zeit

Open access · goldAbstract readComparative Study
In one paragraph

Article in Acta veterinaria Scandinavica, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Christin RöttigerClinic for Horses, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559, Hannover, Germany. Christin.Roettiger@tiho-hannover.de.ORCID http://orcid.org/0000-0001-5486-1840
Maren HelligeClinic for Horses, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559, Hannover, Germany.
Bernhard OhnesorgeClinic for Horses, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559, Hannover, Germany.
Astrid Bienert-ZeitClinic for Horses, University of Veterinary Medicine Hannover, Foundation, Bünteweg 9, 30559, Hannover, Germany.
University of Veterinary Medicine Hannover, Foundation · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe use of cadavers for radiology research methodologies involving subjective image quality evaluation of anatomical criteria is well-documented. The purpose of this method comparison study was to evaluate the image quality of dental and adjacent structures in computed tomography (CT) and high-field (3 T) magnetic resonance (MR) images in cadaveric heads, based on an objective four-point rating scale. Whilst CT is a well-established technique, MR imaging (MRI) is rarely used for equine dental diagnostics. The use of a grading system in this study allowed an objective assessment of CT and MRI advantages in portraying equine cheek teeth. As imaging is commonly performed with cadaveric or frozen and thawed heads for dental research investigations, the second objective was to quantify the impact of the specimens' conditions (in vivo, post-mortem, frozen-thawed) on the image quality in CT and MRI.

resultsThe CT and MR images of nine horses, focused on the maxillary premolar 08s and molar 09s, were acquired post-mortem (Group A). Three observers scored the dental and adjacent tissues. Results showed that MR sequences gave an excellent depiction of endo- and periodontal structures, whereas CT produced high-quality images of the hard tooth and bony tissues. Additional CT and MRI was performed in vivo (Group B) and frozen-thawed (Group C) in three of these nine horses to specify the condition of the best specimens for further research. Assessing the impact of the specimens' conditions on image quality, specific soft tissues of the maxillary 08s and 09s including adjacent structures (pulps, mucosa of the maxillary sinuses, periodontal ligament, soft tissue inside the infraorbital canal) were graded in group B and C and analysed for significant differences within CT and MR modalities in comparison to group A. Results showed that MRI scores in vivo were superior to the post-mortem and frozen-thawed condition.

conclusionsOn comparing the imaging performance of CT and MRI, both techniques show a huge potential for application in equine dentistry. Further studies are needed to assess the clinical suitability of MRI. For further research investigations it must be considered, that the best MR image quality is provided in live horses.

Indexed as

AnimalsBicuspidCadaverFemaleFreezingHorsesMagnetic Resonance ImagingMaleMaxillaMolarTomography, X-Ray ComputedCheek teethCTEquine dental imagingHigh-field magnetic resonance imagingHorsePeriodontal ligamentScoring system

Identifiers

PMID31823831
PMCPMC6905104
OpenAlexW2996312578

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.