SynthesisThe Cochrane database of systematic reviews2019
Laparoscopic colposuspension for urinary incontinence in women.
Synthesis in The Cochrane database of systematic reviews, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07398144 (Laparoscopic Burch Colposuspension Versus Transobturator Tape in the Treatment of Female Stress Urinary Incontinence. A Prospective Randomized Study), which is not on this map. Cited by 11 papers, 3 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Laparoscopic Burch Colposuspension Versus Transobturator Tape in the Treatment of Female Stress Urinary Incontinence. A Prospective Randomized Study
Who cites it
11 citing papers in PubMed, 3 syntheses or guidelines pooled it.
- Pain and other complications of pelvic mesh: a systematic review of qualitative studies and thematic synthesis of women's accounts.BMJ open · 2024Pooled it
- Single-incision sling operations for urinary incontinence in women.The Cochrane database of systematic reviews · 2023Pooled it
- Conservative interventions for treating urinary incontinence in women: an Overview of Cochrane systematic reviews.The Cochrane database of systematic reviews · 2022Pooled it
- Current practice of colposuspension in the United Kingdom: Results of a national survey.Acta obstetricia et gynecologica Scandinavica · 2026Article
- Fluid intake schedule as a possible risk-stratification factor for urinary incontinence in women during menopause.Przeglad menopauzalny = Menopause review · 2025Article
- 2024 Canadian Urological Association guideline: Female stress urinary incontinence.Canadian Urological Association journal = Journal de l'Association des urologues du Canada · 2024Article
- Comparative study of two techniques of laparoscopic burch colposuspension using sutures versus mesh in women with genuine stress urinary incontinence.Arab journal of urology · 2024Article
- Surgical treatment of stress urinary incontinence: comparison of robotic-assisted Burch urethropexy with retropubic midurethral sling.Journal of robotic surgery · 2023Article
- Burch colposuspension for stress urinary incontinence: a 14-year prospective follow-up.Science China. Life sciences · 2022Article
- The Efficacy and Mid-term Durability of Urethral Sphincter Injections of Platelet-Rich Plasma in Treatment of Female Stress Urinary Incontinence.Frontiers in pharmacology · 2022Article
- Quo Vadis Urogynecology 2020 - Innovative Treatment Concepts for Urinary Incontinence and Pelvic Organ Prolapse.Geburtshilfe und Frauenheilkunde · 2021Article
Corrections and comments
- Update of
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundLaparoscopic colposuspension was one of the first minimal access operations for treating stress urinary incontinence in women, with the presumed advantages of shorter hospital stays and quicker return to normal activities. This Cochrane Review was last updated in 2010.
objectivesTo assess the effects of laparoscopic colposuspension for urinary incontinence in women; and summarise the principal findings of relevant economic evaluations of these interventions. SEARCH
methodsWe searched the Cochrane Incontinence Specialised Register (22 May 2019), which contains trials identified from CENTRAL, MEDLINE, MEDLINE In-Process, MEDLINE Epub Ahead of Print, CINAHL, ClinicalTrials.gov, WHO ICTRP and handsearching of journals and conference proceedings. SELECTION CRITERIA: Randomised controlled trials of women with urinary incontinence that included laparoscopic surgery in at least one arm. DATA COLLECTION AND ANALYSIS: We independently extracted data from eligible trials, assessed risk of bias and implemented GRADE. MAIN
resultsWe included 26 trials involving 2271 women. Thirteen trials (1304 women) compared laparoscopic colposuspension to open colposuspension and nine trials (412 women) to midurethral sling procedures. One trial (161 women) compared laparoscopic colposuspension with one suture to laparoscopic colposuspension with two sutures; and three trials (261 women) compared laparoscopic colposuspension with sutures to laparoscopic colposuspension with mesh and staples. The majority of trials did not follow up participants beyond 18 months. Overall, there was unclear risk of selection, performance and detection bias and generally low risk of attrition and reporting bias. There is little difference between laparoscopic colposuspension using sutures and open colposuspension for subjective cure within 18 months (risk ratio (RR) 1.04, 95% confidence interval (CI) 0.99 to 1.08; 6 trials, 755 women; high-quality evidence). We are uncertain whether laparoscopic colposuspension using mesh and staples is better or worse than open colposuspension for subjective cure within 18 months (RR 0.75, 95% CI 0.61 to 0.93; 3 trials, 362 women; very low-quality evidence) or whether there is a greater risk of repeat continence surgery with laparoscopic colposuspension. Laparoscopic colposuspension may have a lower risk of perioperative complications (RR 0.67, 95% CI 0.47 to 0.94; 11 trials, 1369 women; low-quality evidence). There may be similar or higher rates of bladder perforations with laparoscopic colposuspension (RR 1.72, 95% CI 0.90 to 3.29; 10 trials, 1311 women; moderate-quality evidence). Rates for de novo detrusor overactivity (RR 1.29, 95% CI 0.72 to 2.30; 5 trials, 472 women) and voiding dysfunction (RR 0.81, 95% CI 0.50 to 1.31; 5 trials, 507 women) may be similar but we are uncertain due to the wide confidence interval. Five studies reported on quality of life but we could not synthesise the data. There may be little difference between laparoscopic colposuspension using sutures and tension-free vaginal tape (TVT) for subjective cure within 18 months (RR 1.01, 95% CI 0.88 to 1.16; 4 trials, 256 women; low-quality evidence) or between laparoscopic colposuspension using mesh and staples and TVT (RR 0.71, 95% CI 0.55 to 0.91; 1 trial, 121 women; low-quality evidence). For laparoscopic colposuspension compared with midurethral slings, there may be lower rates of repeat continence surgery (RR 0.40, 95% CI 0.04 to 3.62; 1 trial, 70 women; low-quality evidence) and similar risk of perioperative complications (RR 0.99, 95% CI 0.60 to 1.64; 7 trials, 514 women; low-quality evidence) but we are uncertain due to the wide confidence intervals. There may be little difference in terms of de novo detrusor overactivity (RR 0.80, 95% CI 0.34 to 1.88; 4 trials, 326 women; low-quality evidence); and probably little difference in terms of voiding dysfunction (RR 1.06, 95% CI 0.47 to 2.41; 5 trials, 412 women; moderate-quality evidence) although we are uncertain due to the wide confidence interval. Five studies reported on quality of life but we could not synthesise the data. No studies reported on bladder perforations. Low-quality evidence indicates that there may be higher subjective cure rates within 18 months with two sutures compared to one suture (RR 1.37, 95% CI 1.14 to 1.64; 1 trial, 158 women). Comparing one suture and two sutures, one suture may have lower rates of repeat continence surgery (RR 0.35, 95% CI 0.01 to 8.37; 1 trial, 157 women) and similar risk of perioperative complications (RR 0.88, 95% CI 0.45 to 1.70) but we are uncertain due to the wide 95% CIs. There may be higher rates of voiding dysfunction with one suture compared to two sutures (RR 2.82; 95% CI 0.30 to 26.54; 1 trial, 158 women; low-quality evidence), but we are uncertain due to the wide confidence interval. This trial did not report bladder perforations, de novo detrusor overactivity or quality of life. We are uncertain whether laparoscopic colposuspension with sutures is better or worse for subjective cure within 18 months compared to mesh and staples (RR 1.24, 95% CI 0.96 to 1.59; 2 trials, 180 women; very low-quality evidence) or in terms of repeat continence surgery (RR 0.97, 95% CI 0.06 to 14.91; 1 trial, 69 women; very low-quality evidence). Laparoscopic colposuspension with sutures may increase the number of perioperative complications compared to mesh and staples (RR 1.94, 95% CI 1.09 to 3.48; 3 trials, 260 women; low-quality evidence) but rates of de novo detrusor overactivity may be similar (RR 0.72, 95% CI 0.17 to 3.06; 2 trials, 122 women; low-quality evidence), however, we are uncertain due to the wide confidence interval. None of the studies reported bladder perforations, voiding dysfunction or quality of life. AUTHORS'
conclusionsThe data indicate that, in terms of subjective cure of incontinence within 18 months, there is probably little difference between laparoscopic colposuspension and open colposuspension, or between laparoscopic colposuspension and midurethral sling procedures. Much of the evidence is low quality, meaning that a considerable degree of uncertainty remains about laparoscopic colposuspension. Future trials should recruit adequate numbers, conduct long-term follow-up and measure clinically important outcomes. A brief economic commentary identified three studies. We have not quality-assessed them and they should be interpreted in light of the findings on clinical effectiveness.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.