Evidence map›Paper›PMID 31816886›Full record

ArticleSensors (Basel, Switzerland)2019

Development of an Error Model for a Factory-Calibrated Continuous Glucose Monitoring Sensor with 10-Day Lifetime.

Martina Vettoretti, Cristina Battocchio, Giovanni Sparacino, Andrea Facchinetti

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.2field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 30 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Martina VettorettiDepartment of Information Engineering, University of Padova, 35131 Padova, Italy.
Cristina BattocchioDepartment of Information Engineering, University of Padova, 35131 Padova, Italy.
Giovanni SparacinoDepartment of Information Engineering, University of Padova, 35131 Padova, Italy.ORCID 0000-0002-3248-1393
Andrea FacchinettiDepartment of Information Engineering, University of Padova, 35131 Padova, Italy.ORCID 0000-0001-8041-2280
University of Padua · IT

Funding

Ministero dell'Istruzione, dell'Università e della Ricerca Law 232/2016
6 · The paper itself

Abstract

Factory-calibrated continuous glucose monitoring (FC-CGM) sensors are new devices used in type 1 diabetes (T1D) therapy to measure the glucose concentration almost continuously for 10-14 days without requiring any in vivo calibration. Understanding and modelling CGM errors is important when designing new tools for T1D therapy. Available literature CGM error models are not suitable to describe the FC-CGM sensor error, since their domain of validity is limited to 12-h time windows, i.e., the time between two consecutive in vivo calibrations. The aim of this paper is to develop a model of the error of FC-CGM sensors. The dataset used contains 79 FC-CGM traces collected by the Dexcom G6 sensor. The model is designed to dissect the error into its three main components: effect of plasma-interstitium kinetics, calibration error, and random measurement noise. The main novelties are the model extension to cover the entire sensor lifetime and the use of a new single-step identification procedure. The final error model, which combines a first-order linear dynamic model to describe plasma-interstitium kinetics, a second-order polynomial model to describe calibration error, and an autoregressive model to describe measurement noise, proved to be suitable to describe FC-CGM sensor errors, in particular improving the estimation of the physiological time-delay.

Indexed as

Insulin Infusion SystemsAlgorithmsBayes TheoremBlood GlucoseBlood Glucose Self-MonitoringCalibrationDiabetes Mellitus, Type 1HumansKineticsLongitudinal StudiesModels, TheoreticalReproducibility of ResultsBlood Glucosecalibration errorcontinuous glucose monitoringglucose sensormeasurement errormodelingparameter estimation

Identifiers

PMID31816886
PMCPMC6928894
OpenAlexW2993729518

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.