Characterization of continuous bed motion effects on patient breathing and respiratory motion correction in PET/CT imaging.

Joseph G Meier, Jeremy J Erasmus, Gregory W Gladish, Christine B Peterson, Radwan H Diab, Osama R Mawlawi

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Joseph G MeierDepartment of Imaging Physics - Unit 1352, MD Anderson Cancer Center, Houston, TX, USA.
Jeremy J ErasmusThoracic Imaging Department - Unit 1478, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
Gregory W GladishThoracic Imaging Department - Unit 1478, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
Christine B PetersonBiostatistics Department - Unit 1411, The University of Texas MD Anderson Cancer Center, Houston, TX, USA.
Radwan H DiabFaculty of Medicine, American University of Beirut, Beirut, Lebanon.
Osama R MawlawiDepartment of Imaging Physics - Unit 1352, MD Anderson Cancer Center, Houston, TX, USA.
The University of Texas MD Anderson Cancer Center · USAmerican University of Beirut · LB

Funding

Tumor Evolution and Metastasis ProgramP30CA016672 · NCI · UNIVERSITY OF TX MD ANDERSON CAN CTR · PI Scott Kopetz · 1985 to 2026
$290.8M
CCSG P30CA016672NCINCI NIH HHS P30 CA016672NIHSIEMENS
6 · The paper itself

Abstract

Continuous bed motion (CBM) was recently introduced as an alternative to step-and-shoot (SS) mode for PET/CT data acquisition. In CBM, the patient is continuously advanced into the scanner at a preset speed, whereas in SS, the patient is imaged in overlapping bed positions. Previous investigations have shown that patients preferred CBM over SS for PET data acquisition. In this study, we investigated the effect of CBM versus SS on patient breathing and respiratory motion correction. One hundred patients referred for PET/CT were scanned using a Siemens mCT scanner. Patient respiratory waveforms were recorded using an Anzai system and analyzed using four methods: Methods 1 and 2 measured the coefficient of variation (COV) of the respiratory cycle duration (RCD) and amplitude (RCA). Method 3 measured the respiratory frequency signal prominence (RSP) and method 4 measured the width of the HDChest optimal gate (OG) window when using a 35% duty cycle. Waveform analysis was performed over the abdominothoracic region which exhibited the greatest respiratory motion and the results were compared between CBM and SS. Respiratory motion correction was assessed by comparing the ratios of SUVmax, SUVpeak, and CNR of focal FDG uptake, as well as Radiologists' visual assessment of corresponding image quality of motion corrected and uncorrected images for both acquisition modes. The respiratory waveforms analysis showed that the RCD and RCA COV were 3.7% and 33.3% lower for CBM compared to SS, respectively, while the RSP and OG were 30.5% and 2.0% higher, respectively. Image analysis on the other hand showed that SUVmax, SUVpeak, and CNR were 8.5%, 4.5%, and 3.4% higher for SS compared to CBM, respectively, while the Radiologists' visual comparison showed similar image quality between acquisition modes. However, none of the results showed statistically significant differences between SS and CBM, suggesting that motion correction is not impacted by acquisition mode.

Indexed as

MovementRespirationFemaleFluorodeoxyglucose F18HumansImage Processing, Computer-AssistedMaleMiddle AgedNeoplasmsPositron Emission Tomography Computed TomographyPrognosisProspective StudiesRadiopharmaceuticalsRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedFluorodeoxyglucose F18Radiopharmaceuticalscontinuous bed motionlesion detectabilitypatient breathing repeatabilityPET/CTrespiratory motion correctionSUV quantification

Identifiers

PMID31816183
PMCPMC6964757
OpenAlexW2992166482

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.