ArticleProceedings of SPIE--the International Society for Optical Engineering2019
Quantitative Evaluation of Bone Microstructure using High-Resolution Extremity Cone-Beam CT with a CMOS Detector.
Article in Proceedings of SPIE--the International Society for Optical Engineering, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Comparison of Subjective Image Quality of Mobile C-Arms Equipped with a-Si, CMOS or IGZO Flat-Panel Detectors for Intraoperative Fluoroscopy.Journal of imaging · 2026Article
- Development and evaluation of an ultra-high-resolution cone-beam computed tomography system for hand and foot.Skeletal radiology · 2026Article
- Subchondral bone in knee osteoarthritis: bystander or treatment target?Skeletal radiology · 2023Review
- Flat-panel conebeam CT in the clinic: history and current state.Journal of medical imaging (Bellingham, Wash.) · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
purposeA high-resolution cone-beam CT (CBCT) system for extremity imaging has been developed using a custom complementary metal-oxide-semiconductor (CMOS) x-ray detector. The system has spatial resolution capability beyond that of recently introduced clinical orthopedic CBCT. We evaluate performance of this new scanner in quantifying trabecular microstructure in subchondral bone of the knee.
methodsThe high-resolution scanner uses the same mechanical platform as the commercially available Carestream OnSight 3D extremity CBCT, but replaces the conventional amorphous silicon flat-panel detector (a-Si:H FPD with 0.137 mm pixels and a ~0.7 mm thick scintillator) with a Dalsa Xineos3030 CMOS detector (0.1 mm pixels and a custom 0.4 mm scintillator). The CMOS system demonstrates ~40% improved spatial resolution (FWHM of a ~0.1 mm tungsten wire) and ~4× faster scan time than FPD-based extremity CBCT (FPD-CBCT). To investigate potential benefits of this enhanced spatial resolution in quantitative assessment of bone microstructure, 26 trabecular core samples were obtained from four cadaveric tibias and imaged using FPD-CBCT (75 μm voxels), CMOS-CBCT (75 μm voxels), and reference micro-CT (μCT, 15 μm voxels). CBCT bone segmentations were obtained using local Bernsen's thresholding combined with global histogram-based pre-thresholding; μCT segmentation involved Otsu's method. Measurements of trabecular thickness (Tb.Th), spacing (Tb.Sp), number (Tb.N) and bone volume (BV/TV) were performed in registered regions of interest in the segmented CBCT and μCT reconstructions.
resultsCMOS-CBCT achieved noticeably improved delineation of trabecular detail compared to FPD-CBCT. Correlations with reference μCT for metrics of bone microstructure were better for CMOS-CBCT than FPD-CBCT, in particular for Tb.Th (increase in Pearson correlation from 0.84 with FPD-CBCT to 0.96 with CMOS-CBCT) and Tb.Sp (increase from 0.80 to 0.85). This improved quantitative performance of CMOS-CBCT is accompanied by a reduction in scan time, from ~60 sec for a clinical high resolution protocol on FPD-CBCT to ~17 sec for CMOS-CBCT.
conclusionThe CMOS-based extremity CBCT prototype achieves improved performance in quantification of bone microstructure, while retaining other diagnostic capabilities of its FPD-based precursor, including weight-bearing imaging. The new system offers a promising platform for quantitative imaging of skeletal health in osteoporosis and osteoarthritis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials