Evidence map›Paper›PMID 31811793›Full record

ArticleMedical physics2019

Impact of the non-negativity constraint in model-based iterative reconstruction from CT data.

Viktor Haase, Katharina Hahn, Harald Schöndube, Karl Stierstorfer, Andreas Maier, Frédéric Noo

Abstract read
In one paragraph

Article in Medical physics, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. A Robust Regularizer for Multiphase CT.IEEE transactions on medical imaging · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Viktor HaaseSiemens Healthcare GmbH, Siemensstr. 3, 91301, Forchheim, Germany.
Katharina HahnSiemens Healthcare GmbH, Siemensstr. 3, 91301, Forchheim, Germany.
Harald SchöndubeSiemens Healthcare GmbH, Siemensstr. 3, 91301, Forchheim, Germany.
Karl StierstorferSiemens Healthcare GmbH, Siemensstr. 3, 91301, Forchheim, Germany.
Andreas MaierPattern Recognition Lab, Department of Computer Science, Friedrich-Alexander-Universität Erlangen-Nürnberg, Martensstr. 3, 91058, Erlangen, Germany.
Frédéric NooDepartment of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, 84108, USA.

Funding

Novel Reconstruction Paradigm for Multiphasic CT Imaging of Kidney CancerR21CA211035 · NCI · UNIVERSITY OF UTAH · PI NOO, FREDERIC, XU, JINGYAN · 2017 to 2018
$386k
NCI NIH HHS R21 CA211035Siemens Healthcare GmbHU.S. National Institutes of Health R21CA211035
6 · The paper itself

Abstract

purposeModel-based iterative reconstruction is a promising approach to achieve dose reduction without affecting image quality in diagnostic x-ray computed tomography (CT). In the problem formulation, it is common to enforce non-negative values to accommodate the physical non-negativity of x-ray attenuation. Using this a priori information is believed to be beneficial in terms of image quality and convergence speed. However, enforcing non-negativity imposes limitations on the problem formulation and the choice of optimization algorithm. For these reasons, it is critical to understand the value of the non-negativity constraint. In this work, we present an investigation that sheds light on the impact of this constraint.

methodsWe primarily focus our investigation on the examination of properties of the converged solution. To avoid any possibly confounding bias, the reconstructions are all performed using a provably converging algorithm started from a zero volume. To keep the computational cost manageable, an axial CT scanning geometry with narrow collimation is employed. The investigation is divided into five experimental studies that challenge the non-negativity constraint in various ways, including noise, beam hardening, parametric choices, truncation, and photon starvation. These studies are complemented by a sixth one that examines the effect of using ordered subsets to obtain a satisfactory approximate result within 50 iterations. All studies are based on real data, which come from three phantom scans and one clinical patient scan. The reconstructions with and without the non-negativity constraint are compared in terms of image similarity and convergence speed. In select cases, the image similarity evaluation is augmented with quantitative image quality metrics such as the noise power spectrum and closeness to a known ground truth.

resultsFor cases with moderate inconsistencies in the data, associated with noise and bone-induced beam hardening, our results show that the non-negativity constraint offers little benefit. By varying the regularization parameters in one of the studies, we observed that sufficient edge-preserving regularization tends to dilute the value of the constraint. For cases with strong data inconsistencies, the results are mixed: the constraint can be both beneficial and deleterious; in either case, however, the difference between using the constraint or not is small relative to the overall level of error in the image. The results with ordered subsets are encouraging in that they show similar observations. In terms of convergence speed, we only observed one major effect, in the study with data truncation; this effect favored the use of the constraint, but had no impact on our ability to obtain the converged solution without constraint.

conclusionsOur results did not highlight the non-negativity constraint as being strongly beneficial for diagnostic CT imaging. Altogether, we thus conclude that in some imaging scenarios, the non-negativity constraint could be disregarded to simplify the optimization problem or to adopt other forward projection models that require complex optimization machinery to be used together with non-negativity.

Indexed as

Models, TheoreticalTomography, X-Ray ComputedAlgorithmsArtifactsHipHumansImage Processing, Computer-AssistedMetalsPhantoms, ImagingRadiation DosageMetalsmodel-based iterative reconstructionnon-negativity constraintpenalized weighted least-squarespositivity constraintx-ray computed tomography

Identifiers

PMID31811793
PMCPMC7852321

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.