ArticleClinical research in cardiology : official journal of the German Cardiac Society2020
Comparison of current German and European practice in cardiac resynchronization therapy: lessons from the ESC/EHRA/HFA CRT Survey II.
Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Distribution and impact of age in patients with implantable cardioverter-defibrillators regarding early complications and 1-year clinical outcome: results from the German Device Registry.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2021Article
- Significance of myeloperoxidase plasma levels as a predictor for cardiac resynchronization therapy response.Clinical research in cardiology : official journal of the German Cardiac Society · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe European CRT Survey II was introduced to offer insights into CRT implantation practice in Europe. We compared the national data from the participating German centres with that of the other European countries with regard to differences in patient selection, implant results, and initial properties. METHODS AND
results11,088 patients were enrolled in 288 centres from 42 countries between 2015 and 2017. Of these, 675 (6.1%) were included in 17 centres in Germany. Patients from Germany were older, had more comorbidities and more symptoms of heart failure (HF) than patients from other European countries. There were no differences with regard to HF aetiology and guideline-directed medical treatment was overall well implemented. There was a high use of CRT in patients with atrial fibrillation, even higher in German patients. CRT was most often applied due to HF with wide QRS complex (class I recommendation) but with relatively higher frequency in Germany due to HF with primary indication for an implantable cardioverter-defibrillator (class IIb) or a pacemaker with expected pacing dependency (class I). The overall implant success rate was high with some differences in the implant procedure. The use of remote monitoring was lower in Germany.
conclusionThis analysis from the European CRT Survey II overall shows good guideline adherence, high implantation success and a low rate of complications in daily practice. There are some regional differences in baseline characteristics, CRT indication, and procedural aspects. The use of remote monitoring in Germany lags behind other European countries.