Evidence map›Paper›PMID 31805942›Full record

ArticleBiomedical engineering online2019

A current-mode system to self-measure temperature on implantable optoelectronics.

Fahimeh Dehkhoda, Ahmed Soltan, Nikhil Ponon, Anthony O'Neill, Andrew Jackson, Patrick Degenaar

Abstract read
In one paragraph

Article in Biomedical engineering online, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Fahimeh DehkhodaSchool of Engineering, Institute for Integrated Micro and Nano Systems, University of Edinburgh, Edinburgh, EH9 3JL, UK. f.dehkhoda@ed.ac.uk.ORCID http://orcid.org/0000-0002-7399-7169
Ahmed SoltanNISC Group, Nile University, Al Sheikh Zayed, Giza, Egypt.
Nikhil PononSchool of Engineering, Newcastle University, Newcastle, NE1 7RU, UK.
Anthony O'NeillSchool of Engineering, Newcastle University, Newcastle, NE1 7RU, UK.
Andrew JacksonInstitute of Neuroscience, Faculty of Medical Sciences, Newcastle University, Newcastle, NE2 4HH, UK.
Patrick DegenaarSchool of Engineering, Newcastle University, Newcastle, NE1 7RU, UK.

Funding

Engineering and Physical Sciences Research Council NS/A000026/1Wellcome Trust 102037
6 · The paper itself

Abstract

backgroundOne of the major concerns in implantable optoelectronics is the heat generated by emitters such as light emitting diodes (LEDs). Such devices typically produce more heat than light, whereas medical regulations state that the surface temperature change of medical implants must stay below + 2 °C. The LED's reverse current can be employed as a temperature-sensitive parameter to measure the temperature change at the implant's surface, and thus, monitor temperature rises. The main challenge in this approach is to bias the LED with a robust voltage since the reverse current is strongly and nonlinearly sensitive to the bias voltage.

methodsTo overcome this challenge, we have developed an area-efficient LED-based temperature sensor using the LED as its own sensor and a CMOS electronic circuit interface to ensure stable bias and current measurement. The circuit utilizes a second-generation current conveyor (CCII) configuration to achieve this and has been implemented in 0.35 μm CMOS technology.

resultsThe developed circuits have been experimentally characterized, and the temperature-sensing functionality has been tested by interfacing different mini-LEDs in saline models of tissue prior to in vivo operation. The experimental results show the functionality of the CMOS electronics and the efficiency of the CCII-based technique with an operational frequency up to 130 kHz in achieving a resolution of 0.2 °C for the surface temperature up to + 45 °C.

conclusionsWe developed a robust CMOS current-mode sensor interface which has a reliable CCII to accurately convey the LED's reverse current. It is low power and robust against power supply ripple and transistor mismatch which makes it reliable for sensor interface. The achieved results from the circuit characterization and in vivo experiments show the feasibility of the whole sensor interface in monitoring the tissue surface temperature in optogenetics.

Indexed as

LightProstheses and ImplantsTemperatureAnimalsElectrical Equipment and SuppliesElectric ConductivityEquipment DesignHumansCMOS sensor interfaceCurrent conveyorLEDOptogeneticsTemperature sensor

Identifiers

PMID31805942
PMCPMC6896326

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.