Evidence map›Paper›PMID 31805621›Full record

ArticleJournal of cardiovascular imaging2020

Simultaneous Assessment of Left Ventricular Function and Coronary Artery Anatomy by Third-generation Dual-source Computed Tomography Using a Low Radiation Dose.

Ji Won Lee, Kyung Jin Nam, Jin You Kim, Yeon Joo Jeong, Geewon Lee, So Min Park, Soo Jin Lim, Ki Seok Choo

Abstract read
In one paragraph

Article in Journal of cardiovascular imaging, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Is SPECT LVEF assessment more accurate than CT at higher heart rates? More evidence for complementary information in multimodality imaging.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ji Won LeeDepartment of Radiology, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Hospital, Busan, Korea.ORCID https://orcid.org/0000-0003-1800-8548
Kyung Jin NamDepartment of Radiology, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Yangsan Hospital, Yangsan, Korea.ORCID https://orcid.org/0000-0001-5118-1903
Jin You KimDepartment of Radiology, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Hospital, Busan, Korea.ORCID https://orcid.org/0000-0002-9631-501X
Yeon Joo JeongDepartment of Radiology, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Hospital, Busan, Korea.ORCID https://orcid.org/0000-0002-1741-9604
Geewon LeeDepartment of Radiology, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Hospital, Busan, Korea.ORCID https://orcid.org/0000-0002-8278-0500
So Min ParkDepartment of Radiology, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Hospital, Busan, Korea.ORCID https://orcid.org/0000-0002-8885-0872
Soo Jin LimDepartment of Cardiology, Kim Hae Kangil Hospital, Gimhae, Korea.ORCID https://orcid.org/0000-0002-8023-4995
Ki Seok ChooDepartment of Radiology, Pusan National University School of Medicine and Medical Research Institute, Pusan National University Yangsan Hospital, Yangsan, Korea. kschoo0618@naver.com.ORCID https://orcid.org/0000-0001-5072-4259

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTo assess left ventricular function and coronary artery simultaneously by third-generation dual-source computed tomography (CT) using a low radiation dose.

methodsA total of 48 patients (36 men, 12 women; mean age 57.0 ± 9.5 years) who underwent both electrocardiography-gated cardiac CT angiography (CCTA) using 70-90 kVp and echocardiography were included in this retrospective study. The correlation between left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), and left ventricular ejection fraction (LVEF) measured using CCTA and echocardiography was determined. The quality of coronary artery images was analyzed using a 4-point scale (1, excellent; 4, poor). The effective radiation dose of CCTA was calculated.

resultsMean heart rate during the CT examination was 59.9 ± 9.9 bpm (range 38-79) and the body mass index of 48 patients was 24.5 ± 2.6 kg/m² (range 17.0-29.4). LVEDV, LVESV, and LVEF measured using CCTA and echocardiography demonstrated a fair to moderate correlation (Pearson correlation coefficient: r = 0.395, p = 0.005 for LVEDV; r = 0.509. p < 0.001 for LVESV; r = 0.551, p < 0.001 for LVEF). Average image quality score of coronary arteries was 1.0 ± 0.1 (range 1-2). A total of 99.0% (783 of 791) of segments had an excellent image quality score, and 1.0% (8 of 791) of segments had a good score. Mean effective radiation dose was 2.2 ± 0.7 mSv.

conclusionsThird-generation dual-source CT using a low tube voltage simultaneously provides information regarding LV function and coronary artery disease at a low radiation dose. It can serve as an alternative option for functional assessment, particularly when other imaging modalities are inadequate.

Indexed as

Coronary vesselsEchocardiographyLeft ventricular functionMultidetector computed tomographyRadiation dosage

Identifiers

PMID31805621
PMCPMC6992922

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked