Evidence map›Paper›PMID 31805550›Full record

ArticleOphthalmic research2020

Reliability of Mesopic Measures of Visual Acuity and Contrast Sensitivity and Their Correlation with Rod and Cone Function in Retinitis Pigmentosa.

Ava K Bittner, Mariana C Ferraz

Abstract read
In one paragraph

Article in Ophthalmic research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Age-related normal limits for spatial vision.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2022
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Ava K BittnerDepartment of Ophthalmology, Stein Eye Institute, University of California, Los Angeles, Los Angeles, California, USA, abittne1@jhmi.edu.
Mariana C FerrazCollege of Optometry, Nova Southeastern University, Fort Lauderdale, Florida, USA.

Funding

Modulating Ocular/Retinal Blood Flow and Visual Function in Retinitis PigmentosaR21EY023720 · NEI · NOVA SOUTHEASTERN UNIVERSITY · PI BITTNER, AVA K · 2013 to 2013
$227k
NEI NIH HHS R21 EY023720
6 · The paper itself

Abstract

backgroundMesopic conditions elicit both rod and cone responses, and they are more commonly encountered in daily life than are scotopic conditions; yet visual function outcome measures of mesopic visual acuity (VA) or contrast sensitivity (CS) are rarely evaluated.

objectiveIn retinitis pigmentosa (RP), we explored whether visual reductions in mesopic versus photopic conditions were correlated with cone or rod function, as well as the between-visit test-retest variability in mesopic measures.

methodsAt each of two visits, 22 RP subjects completed mesopic and photopic ETDRS VA and Pelli-Robson chart CS tests obtained with and without a U23 NoIR 4% transmission filter; testing of perifoveal scotopic cone or rod sensitivity with the AdaptDx; and the Rabin Cone Contrast Test (CCT).

resultsA greater CS reduction in mesopic versus photopic conditions was significantly related to absence of scotopic rod function (p = 0.038) or longer self-reported duration of night vision loss (p = 0.044). VA reductions >0.2 logMAR in mesopic versus photopic conditions were significantly related to reduced cone-mediated scotopic sensitivity (p = 0.038). Significant predictors of the CCT ratio of S-cone to M- and L-cone sensitivity were mesopic VA (p = 0.038) and absence of AdaptDx rod function (p = 0.008). Test-retest 95% coefficients of repeatability were not significantly different when comparing between photopic and mesopic tests of VA (0.16 and 0.12 logMAR, respectively) or CS (0.21 and 0.24 logCS, respectively).

conclusionsPerifoveal scotopic rod and cone function measured with the AdaptDx was significantly correlated with mesopic CS and VA, respectively, which had good, acceptable test-retest repeatability; thus, they appear to be suitable outcome measures to monitor mesopic visual function in clinical practice or trials. RP subjects with reduced mesopic VA and no perifoveal rod function had a greater loss of sensitivity for S-cones than for L-/M-cones.

Indexed as

Visual AcuityAdultContrast SensitivityFemaleFollow-Up StudiesHumansMaleMesopic VisionMiddle AgedReproducibility of ResultsRetinal Cone Photoreceptor CellsRetinal Rod Photoreceptor CellsRetinitis PigmentosaRetrospective StudiesVisual FieldsCone sensitivityContrast sensitivityRetinitis pigmentosaRod functionScotopicVisual acuity

Identifiers

PMID31805550
PMCPMC10053993

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.