ArticlePloS one2019
Limits in reliability of leg-spring and joint stiffness measures during single-leg hopping within a sled-based system.
Article in PloS one, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Research examining the reliability of stiffness measures during hopping has shown strong consistency in leg-spring stiffness (kleg), but high variability in joint stiffness (kjoint) measures. Sled-based systems (SBS) reduce movement degrees-of-freedom and are used to examine stretch-shortening cycle (SSC) function under controlled conditions. The aim of this study was to examine the reliability of kleg and kjoint during single-leg hopping within an SBSKinematic and kinetic data were collected on four occasions (Day_1, Day_2, Day_3 and Day_3Offset). Participants completed two trials of single-leg hopping at different frequencies (1.5, 2.2 and 3.0 Hz) while attached to an inclined-SBS. Stiffness was determined using models of leg-spring (kleg) and torsional (kjoint) stiffness. Statistical analysis identified absolute and relative measures of reliability. Results showed moderate reliability for kleg at 1.5 Hz between inter-day testing bouts, and weak consistency at 2.2 and 3.0 Hz. Examination of intra-day comparisons showed weak agreement for repeated measures of kleg at 1.5 and 2.2 Hz, but moderate agreement at 3.0 Hz. Limits in kleg reliability were accompanied by weak-to-moderate agreement in kjoint measures across inter- and intra-day testing bouts. Results showed limits in the reliability of stiffness measures relative to previous reports on overground hopping. Lack of consistency in kleg and kjoint may be due to the novelty of hopping within the current inclined-SBS. Constraints imposed on the hopping task resulting from SBS design (e.g. additional chair mass, restricting upper body movement) may have also influenced limits in kleg and kjoint reliability. Researchers should consider these findings when employing inclined-SBS of a similar design to examine SSC function.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.