ArticleNan fang yi ke da xue xue bao = Journal of Southern Medical University2019
[Sparse-view helical CT reconstruction based on tensor total generalized variation minimization].
Article in Nan fang yi ke da xue xue bao = Journal of Southern Medical University, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveWe propose a sparse-view helical CT iterative reconstruction algorithm based on projection of convex set tensor total generalized variation minimization (TTGV-POCS) to reduce the X-ray dose of helical CT scanning.
methodsThe three-dimensional volume data of helical CT reconstruction was viewed as the third-order tensor. The tensor generalized total variation (TTGV) was used to describe the structural sparsity of the three-dimensional image. The POCS iterative reconstruction framework was adopted to achieve a robust result of sparse-view helical CT reconstruction. The TTGV-POCS algorithm fully used the structural sparsity of first-order and second-order derivation and the correlation between the slices of helical CT image data to effectively suppress artifacts and noise in the image of sparse-view reconstruction and better preserve image edge information.
resultsThe experimental results of XCAT phantom and patient scan data showed that the TTGVPOCS algorithm had better performance in reducing noise, removing artifacts and maintaining edges than the existing reconstruction algorithms. Comparison of the sparse-view reconstruction results of XCAT phantom data with 144 exposure views showed that the TTGV-POCS algorithm proposed herein increased the PSNR quantitative index by 9.17%-15.24% compared with the experimental comparison algorithm; the FSIM quantitative index was increased by 1.27%-9.30%.
conclusionsThe TTGV-POCS algorithm can effectively improve the image quality of helical CT sparse-view reconstruction and reduce the radiation dose of helical CT examination to improve the clinical imaging diagnosis.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.