ArticleTrauma surgery & acute care open2019
Intraoperative REBOA: an analysis of the American Association for the Surgery of Trauma AORTA registry.
Article in Trauma surgery & acute care open, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Endovascular management of haemorrhage and vascular lesions in patients with multiple and/or severe injuries: a systematic review and clinical practice guideline update.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2025Pooled it
- Resuscitative endovascular balloon occlusion of the aorta (REBOA) in patients with major trauma and uncontrolled haemorrhagic shock: a systematic review with meta-analysis.World journal of emergency surgery : WJES · 2021Pooled it
- A Case of Hemorrhagic Shock for a Ruptured Splenic Aneurysm Treated With REBOA-Assisted Surgery.Case reports in surgery · 2025Article
- Article
- Class of hemorrhagic shock is associated with progressive diastolic coronary flow reversal and diminished left ventricular function.Frontiers in physiology · 2022Article
- Clinical Impact of a Dedicated Trauma Hybrid Operating Room.Journal of the American College of Surgeons · 2021Article
- Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA): update and insights into current practices and future directions for research and implementation.Scandinavian journal of trauma, resuscitation and emergency medicine · 2021Review
- Determination of optimal deployment strategy for REBOA in patients with non-compressible hemorrhage below the diaphragm.Trauma surgery & acute care open · 2021Article
- Hate to Burst Your Balloon: Successful REBOA Use Takes More Than a Course.Journal of endovascular resuscitation and trauma management · 2020Article
- Combined, converted, and prophylactic use of resuscitative endovascular balloon occlusion of the aorta for severe torso trauma: a retrospective study.Acute medicine & surgeryArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
16 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundResuscitative endovascular balloon occlusion of the aorta (REBOA) is a less-invasive technique for aortic occlusion (AO). Commonly performed in the emergency department (ED), the role of intraoperative placement is less defined. We hypothesized that operating room (OR) placement is associated with increased in-hospital mortality.
methodsThe American Association for the Surgery of Trauma AORTA registry was used to identify patients undergoing REBOA. Injury characteristics and outcomes data were compared between OR and ED groups. The primary outcome was in-hospital mortality; secondary outcomes included total AO time, transfusion requirements, and acute kidney injury.
resultsLocation and timing of catheter insertion were available for 305 of 321 (95%) subjects. 58 patients underwent REBOA in the OR (19%). There were no differences with respect to sex, admission lactate, and Injury Severity Score. The OR group was younger (33 years vs. 41 years, p=0.01) and with more penetrating injuries (36% vs. 15%, p<0.001). There were significant differences with respect to admission physiology. Time from admission to AO was longer in the OR group (75 minutes vs. 23 minutes, p<0.001) as was time to definitive hemostasis (116 minutes vs. 79 minutes, p=0.01). Unadjusted mortality was lower in the OR group (36.2% vs. 68.8%, p<0.001). There were no differences in secondary outcomes. After controlling for covariates, there was no association between insertion location and in-hospital mortality (OR 1.8, 95% CI 0.30 to 11.50). DISCUSSION: OR REBOA placement is common and generally employed in patients with more stable admission physiology. OR placement was not associated with increased in-hospital mortality despite longer times to AO and definite hemostasis when compared with catheters placed in the ED. LEVEL OF EVIDENCE: IV; therapeutic/care management.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.