Evidence map›Paper›PMID 31799054›Full record

ArticleBiomedical optics express2019

Diffuse reflectance spectroscopy accurately identifies the pre-cortical zone to avoid impending pedicle screw breach in spinal fixation surgery.

Gustav Burström, Akash Swamy, Jarich W Spliethoff, Christian Reich, Drazenko Babic, Benno H W Hendriks, Halldor Skulason, Oscar Persson, Adrian Elmi Terander, Erik Edström

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed, 1 pooled it
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 3 countries.

Gustav BurströmDepartment of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.ORCID https://orcid.org/0000-0001-6606-1867
Akash SwamyDelft University of Technology, Department of Biomechanical Engineering, Delft, The Netherlands.
Jarich W SpliethoffDepartment of In-body Systems, Philips Research, Royal Philips NV, Eindhoven, The Netherlands.
Christian ReichDepartment of In-body Systems, Philips Research, Royal Philips NV, Eindhoven, The Netherlands.
Drazenko BabicDepartment of In-body Systems, Philips Research, Royal Philips NV, Eindhoven, The Netherlands.
Benno H W HendriksDelft University of Technology, Department of Biomechanical Engineering, Delft, The Netherlands.
Halldor SkulasonDepartment of Neurosurgery, Landspitali University Hospital, Reykjavik, Iceland.
Oscar PerssonDepartment of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.
Adrian Elmi TeranderDepartment of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.ORCID https://orcid.org/0000-0002-3776-6136
Erik EdströmDepartment of Clinical Neuroscience, Karolinska Institutet, Stockholm, Sweden.
Philips (Netherlands) · NLKarolinska University Hospital · SEReykjavík University · IS

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Pedicle screw placement accuracy during spinal fixation surgery varies greatly and severe misplacement has been reported in 1-6.5% of screws. Diffuse reflectance (DR) spectroscopy has previously been shown to reliably discriminate between tissues in the human body. We postulate that it could be used to discriminate between cancellous and cortical bone. Therefore, the purpose of this study is to validate DR spectroscopy as a warning system to detect impending pedicle screw breach in a cadaveric surgical setting using typical clinical breach scenarios. DR spectroscopy was incorporated at the tip of an integrated pedicle screw and screw driver used for tissue probing during pedicle screw insertions on six cadavers. Measurements were collected in the wavelength range of 400-1600 nm and each insertion was planned to result in a breach. Measurements were labelled as cancellous, cortical or representing a pre-cortical zone (PCZ) in between, based on information from cone beam computed tomographies at corresponding positions. In addition, DR spectroscopy data was recorded after breach. Four typical pedicle breach types were performed, and a total of 45 pedicle breaches were recorded. For each breach direction, the technology was able to detect the transition of the screw tip from the cancellous bone to the PCZ (P < 0.001), to cortical bone (P < 0.001), and to a subsequent breach (P < 0.001). Using support vector machine (SVM) classification, breach could reliably be detected with a sensitivity of 98.3 % [94.3-100 %] and a specificity of 97.7 % [91.0-100 %]. We conclude that DR spectroscopy reliably identifies the area of transition from cancellous to cortical bone in typical breach scenarios and can warn the surgeon of impending pedicle breach, thereby resulting in safer spinal fixation surgeries.

Identifiers

PMID31799054
PMCPMC6865097
OpenAlexW2981878116

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.