ArticleBiomedical optics express2019
Signal averaging improves signal-to-noise in OCT images: But which approach works best, and when?
Article in Biomedical optics express, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
25 citing papers in PubMed.
- A Low-Cost, Lightweight High-Frequency Ultrasound Transducer with Aluminum Electrodes and 3D-Printed Polymer Housing.Biosensors · 2026Article
- Deep Learning-Based Quantification of Vitreous Hyperreflective Foci as a Biomarker for Intraocular Inflammation.Ophthalmology science · 2026Article
- Wavelet time-frequency analysis enhances noise-resilient quantification of corneal wave velocity and natural frequency in optical coherence elastography.Biomedical optics express · 2026Article
- A large-scale coherent 4D imaging sensor.Nature · 2026Article
- Impact of 85 kHz versus 125 kHz SHIFT OCTA scan speeds on image quality in retinal diseases and diagnostic reliability of choroidal neovascular membranes.Scientific reports · 2025Article
- Impact of image averaging on choroidal quantification using swept-source optical coherence tomography.BMC ophthalmology · 2025Article
- Recent Optical Coherence Tomography (OCT) Innovations for Increased Accessibility and Remote Surveillance.Bioengineering (Basel, Switzerland) · 2025Review
- Article
- Quantitative Optimization of Handheld Probe External Pressure on Dermatological Microvasculature Using Optical Coherence Tomography-Based Angiography.Micromachines · 2024Article
- OCTA: Essential or Gimmick?Ophthalmology and therapy · 2024Article
- Optical-coherence-tomography-based deep-learning scatterer-density estimator using physically accurate noise model.Biomedical optics express · 2024Article
- Acetazolamide Challenge Changes Outer Retina Bioenergy-Linked and Anatomical OCT Biomarkers Depending on Mouse Strain.Investigative ophthalmology & visual science · 2024Article
- Polarization-artifact reduction and accuracy improvement of Jones-matrix polarization-sensitive optical coherence tomography by multi-focus-averaging based multiple scattering reduction.Biomedical optics express · 2024Article
- Speckle contrast reduction through the use of a modally-specific photonic lantern for optical coherence tomography.Biomedical optics express · 2023Article
- Fast optical coherence tomography angiography image acquisition and reconstruction pipeline for skin application.Biomedical optics express · 2023Article
- Precision of attenuation coefficient measurements by optical coherence tomography.Journal of biomedical optics · 2022Article
- High-Speed Balanced-Detection Visible-Light Optical Coherence Tomography in the Human Retina Using Subpixel Spectrometer Calibration.IEEE transactions on medical imaging · 2022Article
- Light-adapted flicker optoretinograms captured with a spatio-temporal optical coherence-tomography (STOC-T) system.Biomedical optics express · 2022Article
- Time-domain signal averaging to improve microparticles detection and enumeration accuracy in a microfluidic impedance cytometer.Biotechnology and bioengineering · 2021Article
- Resolution-enhanced OCT and expanded framework of information capacity and resolution in coherent imaging.Scientific reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
The high acquisition speed of state-of-the-art optical coherence tomography (OCT) enables massive signal-to-noise ratio (SNR) improvements by signal averaging. Here, we investigate the performance of two commonly used approaches for OCT signal averaging. We present the theoretical SNR performance of (a) computing the average of OCT magnitude data and (b) averaging the complex phasors, and substantiate our findings with simulations and experimentally acquired OCT data. We show that the achieved SNR performance strongly depends on both the SNR of the input signals and the number of averaged signals when the signal bias caused by the noise floor is not accounted for. Therefore we also explore the SNR for the two averaging approaches after correcting for the noise bias and, provided that the phases of the phasors are accurately aligned prior to averaging, then find that complex phasor averaging always leads to higher SNR than magnitude averaging.
Identifiers
What OpenQuestion holds
Registered trials