ArticleBiomedical engineering letters2019
A compact-sized surface EMG sensor for myoelectric hand prosthesis.
Article in Biomedical engineering letters, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Digital Eye Strain Monitoring for One-Hour Smartphone Engagement Through Eye Activity Measurement System.Journal of eye movement research · 2025Article
- A Highly Efficient HMI Algorithm for Controlling a Multi-Degree-of-Freedom Prosthetic Hand Using Sonomyography.Sensors (Basel, Switzerland) · 2025Article
- Embedded Machine Learning System for Muscle Patterns Detection in a Patient with Shoulder Disarticulation.Sensors (Basel, Switzerland) · 2024Article
- Simulation of a control method for active kinesiotherapy with an upper extremity rehabilitation exoskeleton without force sensor.Journal of neuroengineering and rehabilitation · 2024Article
- Advances in Printed Electronic Textiles.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Review
- Predictors of the masticatory muscle activity during chewing in patients with myogenous temporomandibular disorder.Clinical oral investigations · 2023Observational
- Feature-Classifier Pairing Compatibility for sEMG Signals in Hand Gesture Recognition under Joint Effects of Processing Procedures.Bioengineering (Basel, Switzerland) · 2022Article
- Development and Characterization of Embroidery-Based Textile Electrodes for Surface EMG Detection.Sensors (Basel, Switzerland) · 2022Article
- A low-cost transradial prosthesis controlled by the intention of muscular contraction.Physical and engineering sciences in medicine · 2021Article
- Design of Wearable Electrolarynx with Automatic Control.Journal of medical signals and sensorsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Myoelectric prosthesis requires a sensor that can reliably capture surface electromyography (sEMG) signal from amputees for its controlled operation. The main problems with the presently available EMG devices are their extremely high cost, large response time, noise susceptibility, less amplitude sensitivity, and larger size. This paper proposes a compact and affordable EMG sensor for the prosthetic application. The sensor consists of an electrode interface, signal conditioning unit, and power supply unit all encased in a single package. The performance of dry electrodes employed in the skin interface was compared with the conventional Ag/AgCl electrodes, and the results were found satisfactory. The envelope detection technique in the sensor based on the tuned RC parameters enables the generation of smooth, faster, and repeatable EMG envelope irrespective of signal strength and subject variability. The output performance of the developed sensor was compared with commercial EMG sensor regarding signal-to-noise ratio, sensitivity, and response time. To perform this, EMG data with both devices were recorded for 10 subjects (3 amputees and 7 healthy subjects). The results showed 1.4 times greater SNR values and 45% higher sensitivity of the developed sensor than the commercial EMG sensor. Also, the proposed sensor was 57% faster than the commercial sensor in producing the output response. The sEMG sensor was further tested on amputees to control the operation of a self-designed 3D printed prosthetic hand. With proportional control scheme, the myoelectric hand setup was able to provide quicker and delicate grasping of objects as per the strength of the EMG signal.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.