Evidence map›Paper›PMID 31798887›Full record

ArticleJournal of intensive care2019

Comparison of point-of-care peripheral perfusion assessment using pulse oximetry sensor with manual capillary refill time: clinical pilot study in the emergency department.

Koichiro Shinozaki, Lee S Jacobson, Kota Saeki, Hideaki Hirahara, Naoki Kobayashi, Steve Weisner, Julianne M Falotico, Timmy Li, Junhwan Kim, Lance B Becker

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Journal of intensive care, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04366310 (Capillary Refill Index Measurement with a Temperature Control Procedure), which is not on this map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
2.6field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04366310 terminatednot on this mapstarted 2020, after this paper: background citation

Capillary Refill Index Measurement with a Temperature Control Procedure

TypeobservationalSponsorNihon KohdenRan2020 to 2023Enrolled65ConditionsPeripheral PerfusionArmscapillary refill index, rewarming
3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 27 citations in OpenAlex.

  1. Review
  2. Article
  3. Observational
  4. Observational
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Koichiro Shinozaki1The Feinstein Institute for Medical Research, Northwell Health, 350 Community Dr., Manhasset, NY 11030 USA.ORCID 0000-0001-5500-228X
Lee S Jacobson2Department of Emergency Medicine, North Shore University Hospital, Northwell Health, Manhasset, NY USA.
Kota SaekiNihon Kohden Innovation Center, Cambridge, MA USA.
Hideaki Hirahara4Nihon Kohden Corporation, Tokyo, Japan.
Naoki Kobayashi4Nihon Kohden Corporation, Tokyo, Japan.
Steve WeisnerNihon Kohden Innovation Center, Cambridge, MA USA.
Julianne M Falotico2Department of Emergency Medicine, North Shore University Hospital, Northwell Health, Manhasset, NY USA.
Timmy Li2Department of Emergency Medicine, North Shore University Hospital, Northwell Health, Manhasset, NY USA.
Junhwan Kim1The Feinstein Institute for Medical Research, Northwell Health, 350 Community Dr., Manhasset, NY 11030 USA.
Lance B Becker1The Feinstein Institute for Medical Research, Northwell Health, 350 Community Dr., Manhasset, NY 11030 USA.
Northwell Health · USNihon Kohden (Japan) · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTraditional capillary refill time (CRT) is a manual measurement that is commonly used by clinicians to identify deterioration in peripheral perfusion status. Our study compared a novel method of measuring peripheral perfusion using an investigational device with standardized visual CRT and tested the clinical usefulness of this investigational device, using an existing pulse oximetry sensor, in an emergency department (ED) setting. MATERIAL AND

methodsAn ED attending physician quantitatively measured CRT using a chronometer (standardized visual CRT). The pulse oximetry sensor was attached to the same hand. Values obtained using the device are referred to as blood refill time (BRT). These techniques were compared in its numbers with the Bland-Altman plot and the predictability of patients' admissions.

resultsThirty ED patients were recruited. Mean CRT of ED patients was 1.9 ± 0.8 s, and there was a strong correlation with BRT (

conclusionsBRT by a pulse oximetry sensor was an objective measurement as useful as the standardized CRT measured by the trained examiner with a chronometer at the bedside.

Indexed as

Capillary refill timeOutcome predictionPeripheral perfusion statusVisual assessment

Identifiers

PMID31798887
PMCPMC6880499
OpenAlexW2991226480

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.