Evidence map›Paper›PMID 31797727›Full record

ArticleProceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine2020

Biomechanical assessment of the stability of osteochondral grafts implanted in porcine and bovine femoral condyles.

Philippa Bowland, Raelene M Cowie, Eileen Ingham, John Fisher, Louise M Jennings

Open access · greenAbstract read
In one paragraph

Article in Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
0.9field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 12 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Biomechanical assessment of the stability of osteochondral grafts implanted in porcine and bovine femoral condyles.Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Philippa BowlandInstitute for Medical and Biological Engineering, University of Leeds, Leeds, UK.
Raelene M CowieInstitute for Medical and Biological Engineering, University of Leeds, Leeds, UK.ORCID https://orcid.org/0000-0003-3903-5916
Eileen InghamInstitute for Medical and Biological Engineering, University of Leeds, Leeds, UK.
John FisherInstitute for Medical and Biological Engineering, University of Leeds, Leeds, UK.
Louise M JenningsInstitute for Medical and Biological Engineering, University of Leeds, Leeds, UK.
University of Leeds · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Osteochondral grafts are used clinically to repair cartilage and bone defects and to restore the congruent articulating surfaces of the knee joint following cartilage damage or injury. The clinical success of such osteochondral grafts is heavily reliant on the biomechanical and tribological properties of the surgical repair; however, a limited number of studies have investigated these factors. The aim of this study was to evaluate the influence of graft harvesting and implantation technique as well as bone properties on the primary stability of press-fit implanted osteochondral grafts using a series of uniaxial experimental push-in and push-out tests. Animal (porcine and bovine) knees were used to deliver models of different bone properties (elastic modulus and yield stress). The study showed the graft harvesting method using either a chisel or drill-aided trephine to have no influence on primary graft stability; however, the preparation technique for the graft recipient site was shown to influence the force required to push the graft into the host tissue. For example, when the length of the graft was equal to the recipient site (bottomed), the graft was more stable and dilation of the recipient site was shown to reduce short-term graft stability especially in immature or less dense bone tissue. The push-out tests which compared tissue of different skeletal maturities demonstrated that the maturity of both the graft and host bone tissue to influence the stability of the graft. A higher force was required to push out more skeletally mature grafts from mature bone tissue. The study demonstrates the importance of surgical technique and bone quality/properties on the primary stability and ultimately, the success of osteochondral grafts in the knee.

Indexed as

Cartilage, ArticularFemurKnee JointTransplantsAnimalsBiomechanical PhenomenaCattleElastic ModulusJoint InstabilityModels, BiologicalSwinebiomechanicskneemosaicplastyOsteochondral graftpress-fitprimary stability

Identifiers

PMID31797727
PMCPMC6977152
OpenAlexW2993481431

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.