Evidence map›Paper›PMID 31795358›Full record

ArticleSensors (Basel, Switzerland)2019

Stacked Transistor Bias Circuit of Class-B Amplifier for Portable Ultrasound Systems.

Hojong Choi

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Novel dual-resistor-diode limiter circuit structures for high-voltage reliable ultrasound receiver systems.Technology and health care : official journal of the European Society for Engineering and Medicine · 2022
    Article
  5. Fisheye lens design for solar-powered mobile ultrasound devices.Technology and health care : official journal of the European Society for Engineering and Medicine · 2022
    Article
  6. Article
  7. Article
  8. Development of a low-cost six-axis alignment instrument for flexible 2D and 3D ultrasonic probes.Technology and health care : official journal of the European Society for Engineering and Medicine · 2021
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Hojong ChoiDepartment of Medical IT Convergence Engineering, Kumoh National Institute of Technology, 350-27 Gumi-daero, Gumi 39253, Korea.

Funding

National Research Foundation of Korea NRF-2017R1C1B1003606
6 · The paper itself

Abstract

The performance of portable ultrasound systems is affected by the excessive heat generated by amplifiers, thereby reducing the sensitivity and resolution of the transducer devices used in ultrasound systems. Therefore, the amplifier needs to generate low amounts of heat to stabilize portable ultrasound systems. To properly control the amplifier, the related bias circuit must provide proper DC bias voltages for long time periods in ultrasound systems. To this end, a stacked transistor bias circuit was proposed to achieve a relatively constant amplifier performance irrespective of temperature variance without any cooling systems as the portable ultrasound system structure is limited. To prove the proposed concept, the performance of the gain and DC current consumption at different experimental times was measured and compared to a developed class-B amplifier with different bias circuits. The amplifier with the stacked transistor bias circuit outperformed with regard to the gain and DC current variance versus time (-0.72 dB and 0.065 A, respectively) compared to the amplifier with a typical resistor divider bias circuit (-5.27 dB and 0.237 A, respectively) after a certain time (5 min). Consequently, the proposed stacked transistor bias circuit is a useful electronic device for portable ultrasound systems with limited structure sizes because of its relatively low gain and DC current variance with respect to time.

Indexed as

class-B amplifierportable ultrasound systemstacked transistor bias circuittransducer

Identifiers

PMID31795358
PMCPMC6929050

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.