ArticleSensors (Basel, Switzerland)2019

Validation of a Low-Cost Electromyography (EMG) System via a Commercial and Accurate EMG Device: Pilot Study.

Sergio Fuentes Del Toro, Yuyang Wei, Ester Olmeda, Lei Ren, Wei Guowu, Vicente Díaz

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

29 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. EMG-Controlled Soft Robotic Bicep Enhancement.Bioengineering (Basel, Switzerland) · 2025
    Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Measuring Biosignals with Single Circuit Boards.Bioengineering (Basel, Switzerland) · 2022
    Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sergio Fuentes Del ToroMechanical Engineering Department, Universidad Carlos III de Madrid, Avda. de la Universidad 30, 28911 Leganés, Spain.ORCID 0000-0002-5121-7379
Yuyang WeiSchool of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester M13 9PL, UK.
Ester OlmedaMechanical Engineering Department, Universidad Carlos III de Madrid, Avda. de la Universidad 30, 28911 Leganés, Spain.ORCID 0000-0002-1982-0290
Lei RenSchool of Mechanical, Aerospace and Civil Engineering, University of Manchester, Manchester M13 9PL, UK.
Wei GuowuSchool of Science, Engineering and Environment, University of Salford, Salford M5 4WT, UK.
Vicente DíazMechanical Engineering Department, Universidad Carlos III de Madrid, Avda. de la Universidad 30, 28911 Leganés, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electromyography (EMG) devices are well-suited for measuring the behaviour of muscles during an exercise or a task, and are widely used in many different research areas. Their disadvantage is that commercial systems are expensive. We designed a low-cost EMG system with enough accuracy and reliability to be used in a wide range of possible ways. The present article focuses on the validation of the low-cost system we designed, which is compared with a commercially available, accurate device. The evaluation was done by means of a set of experiments, in which volunteers performed isometric and dynamic exercises while EMG signals from the rectus femoris muscle were registered by both the proposed low-cost system and a commercial system simultaneously. Analysis and assessment of three indicators to estimate the similarity between both signals were developed. These indicated a very good result, with spearman's correlation averaging above 0.60, the energy ratio close to the 80% and the linear correlation coefficient approximating 100%. The agreement between both systems (custom and commercial) is excellent, although there are also some limitations, such as the delay of the signal (<1 s) and noise due to the hardware and assembly in the proposed system.

Indexed as

AdultBiosensing TechniquesElectromyographyFemaleHumansIsometric ContractionMaleMuscle ContractionMuscle, SkeletalYoung Adultelectromyographylow-cost sensorsvalidation

Identifiers

PMID31795083
PMCPMC6928739

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.