Evidence map›Paper›PMID 31793896›Full record

ArticleJMIR rehabilitation and assistive technologies2019

Wrist-Based Accelerometers and Visual Analog Scales as Outcome Measures for Shoulder Activity During Daily Living in Patients With Rotator Cuff Tendinopathy: Instrument Validation Study.

Samuel Larrivée, Frédéric Balg, Guillaume Léonard, Sonia Bédard, Michel Tousignant, Patrick Boissy

2 registry-linked trialsOpen access · goldAbstract read
In one paragraph

Article in JMIR rehabilitation and assistive technologies, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.4field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06939491 naenrolling by invitationnot on this mapstarted 2024, after this paper: background citation

Comparison of Ultrasound-Guided Electrolysis Therapy (USGET) vs. Sham USGET on Patients With Patellar Tendinopathy: A Randomized Controlled Trial (RCT) Assessing the Effects on Pain, Function, and Tendon Structure Including MRI and Shear-wave Elastography Ultrasound Imaging

TypeinterventionalSponsorGymna UniphyRan2024 to 2026Enrolled74ConditionsPatellar Tendinopathy / Jumpers KneeArmsUltrasound guided electrolysis therapy, Sham Electrolysis
NCT07192003 nanot yet recruitingnot on this mapstarted 2025, after this paper: background citation

Comparison of the Immediate Effect of Flossband and Mobilization With Movement on Shoulder Mobility in Volleyball Athletes: A Randomized Clinical Trial

TypeinterventionalSponsorFederal University of ParaíbaRan2025 to 2026Enrolled36ConditionsHealthy Athlete, Shoulder Mobility, Musculoskeletal HealthArmsFloss Band Group (FBG), Mobilization with Movement (MWM) Group
3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 8 citations in OpenAlex.

  1. Trial
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Samuel LarrivéeResearch Center on Aging, Centre intégré universitaire de santé et de services sociaux de l'Estrie, Centre Hospitalier Universitaire de Sherbrooke, Sherbrooke, QC, Canada.ORCID https://orcid.org/0000-0002-3131-143X
Frédéric BalgDepartment of Surgery, Division of Orthopedics, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, QC, Canada.ORCID https://orcid.org/0000-0002-3369-7364
Guillaume LéonardResearch Center on Aging, Centre intégré universitaire de santé et de services sociaux de l'Estrie, Centre Hospitalier Universitaire de Sherbrooke, Sherbrooke, QC, Canada.ORCID https://orcid.org/0000-0002-3625-3072
Sonia BédardDepartment of Surgery, Division of Orthopedics, Faculty of Medicine and Health Sciences, Université de Sherbrooke, Sherbrooke, QC, Canada.ORCID https://orcid.org/0000-0002-8100-5908
Michel TousignantResearch Center on Aging, Centre intégré universitaire de santé et de services sociaux de l'Estrie, Centre Hospitalier Universitaire de Sherbrooke, Sherbrooke, QC, Canada.ORCID https://orcid.org/0000-0001-7561-1170
Patrick BoissyResearch Center on Aging, Centre intégré universitaire de santé et de services sociaux de l'Estrie, Centre Hospitalier Universitaire de Sherbrooke, Sherbrooke, QC, Canada.ORCID https://orcid.org/0000-0001-6582-4519
Université de Sherbrooke · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundShoulder pain secondary to rotator cuff tendinopathy affects a large proportion of patients in orthopedic surgery practices. Corticosteroid injections are a common intervention proposed for these patients. The clinical evaluation of a response to corticosteroid injections is usually based only on the patient's self-evaluation of his function, activity, and pain by multiple questionnaires with varying metrological qualities. Objective measures of upper extremity functions are lacking, but wearable sensors are emerging as potential tools to assess upper extremity function and activity.

objectiveThis study aimed (1) to evaluate and compare test-retest reliability and sensitivity to change of known clinical assessments of shoulder function to wrist-based accelerometer measures and visual analog scales (VAS) of shoulder activity during daily living in patients with rotator cuff tendinopathy convergent validity and (2) to determine the acceptability and compliance of using wrist-based wearable sensors.

methodsA total of 38 patients affected by rotator cuff tendinopathy wore wrist accelerometers on the affected side for a total of 5 weeks. Western Ontario Rotator Cuff (WORC) index; Short version of the Disability of the Arm, Shoulder, and Hand questionnaire (QuickDASH); and clinical examination (range of motion and strength) were performed the week before the corticosteroid injections, the day of the corticosteroid injections, and 2 and 4 weeks after the corticosteroid injections. Daily Single Assessment Numeric Evaluation (SANE) and VAS were filled by participants to record shoulder pain and activity. Accelerometer data were processed to extract daily upper extremity activity in the form of active time; activity counts; and ratio of low-intensity activities, medium-intensity activities, and high-intensity activities.

resultsDaily pain measured using VAS and SANE correlated well with the WORC and QuickDASH questionnaires (r=0.564-0.815) but not with accelerometry measures, amplitude, and strength. Daily activity measured with VAS had good correlation with active time (r=0.484, P=.02). All questionnaires had excellent test-retest reliability at 1 week before corticosteroid injections (intraclass correlation coefficient [ICC]=0.883-0.950). Acceptable reliability was observed with accelerometry (ICC=0.621-0.724), apart from low-intensity activities (ICC=0.104). Sensitivity to change was excellent at 2 and 4 weeks for all questionnaires (standardized response mean=1.039-2.094) except for activity VAS (standardized response mean=0.50). Accelerometry measures had low sensitivity to change at 2 weeks, but excellent sensitivity at 4 weeks (standardized response mean=0.803-1.032).

conclusionsDaily pain VAS and SANE had good correlation with the validated questionnaires, excellent reliability at 1 week, and excellent sensitivity to change at 2 and 4 weeks. Daily activity VAS and accelerometry-derived active time correlated well together. Activity VAS had excellent reliability, but moderate sensitivity to change. Accelerometry measures had moderate reliability and acceptable sensitivity to change at 4 weeks.

Indexed as

activity countsensitivity to changeshouldertest-retestvalidationwearable sensors

Identifiers

PMID31793896
PMCPMC6918212
OpenAlexW2975268913

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.