Evidence map›Paper›PMID 31792850›Full record

ArticleInternational ophthalmology2020

Ocular biometric parameters are associated with non-contact tonometry measured intraocular pressure in non-pathologic myopic patients.

Yazhen Ma, Yanping Ma, Chenli Feng, Minqian Shen, Yuanzhi Yuan

Abstract read
PubMed Publisher
In one paragraph

Article in International ophthalmology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 41% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Yazhen MaTaikang Xianlin Drum Tower Hospital Affiliated to Medical College of Nanjing University, Nanjing, China.
Yanping MaTaikang Xianlin Drum Tower Hospital Affiliated to Medical College of Nanjing University, Nanjing, China.
Chenli FengDepartment of Ophthalmology, Zhongshan Hospital, Fudan University, Shanghai Xuhui District Fenglin Road No. 180, Shanghai, 200032, China.
Minqian ShenDepartment of Ophthalmology, Zhongshan Hospital, Fudan University, Shanghai Xuhui District Fenglin Road No. 180, Shanghai, 200032, China.
Yuanzhi YuanDepartment of Ophthalmology, Zhongshan Hospital, Fudan University, Shanghai Xuhui District Fenglin Road No. 180, Shanghai, 200032, China. yongzhaobj@sina.com.
Nanjing Drum Tower Hospital · CNZhongshan Hospital · CNFudan University · CN

Funding

Science and Technology Commission of Shanghai Municipality 11DZ1921206
6 · The paper itself

Abstract

purposesThis research aimed to investigate effects and risk factors on non-contact tonometer (NCT) readings in healthy myopic subjects by employing cross-sectional study design.

methodsTotally, sixty otherwise healthy myopic volunteers (mean 28.4 years old) with 90% female were recruited in ophthalmic clinic. The routine ophthalmic tests, refractive evaluation, examination central corneal thickness (CCT), depth of anterior chamber, axial length, corneal curvature, white-to-white and NCT were assessed at baseline. The linear-mixed model was utilized to evaluate correlation between the readings and ocular biometric parameters.

resultsFor population in this study, mean spherical equivalents were - 4.85 ± 1.79 diopters in right eyes and - 4.63 ± 1.95 diopters in left eyes. Meanwhile, 28.3% of the eyes had a refractive error exceeding - 6.0 diopters. The mean NCT reading was 15.02 ± 3.02 mmHg in left eyes and 15.33 ± 2.96 mmHg in right eyes. Among the factors analyzed, CCT was the most significant parameter associated with NCT readings. After adjusting for the other factors, per one standard deviation increase of central corneal thickness (36.11 μm) was associated a 1.14 (95% confidence interval 0.53-1.77) mmHg elevated NCT reading. The average central corneal curvature, age and spherical equivalence were also significantly and independently associated with NCT readings.

conclusionsCentral corneal thickness, age, corneal curvature and degree of myopia were independently associated with NCT measured intraocular pressure. Central corneal thickness is one of the most influential factors.

Indexed as

AdultBiometryCorneaCross-Sectional StudiesFemaleHealthy VolunteersHumansIntraocular PressureMaleManometryMyopiaTonometry, OcularCentral corneal thicknessIntraocular pressureMyopiaNon-contact tonometer (NCT)

Identifiers

PMID31792850
OpenAlexW2991979327

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.