Evidence map›Paper›PMID 31792761›Full record

Observational studyJournal of clinical monitoring and computing2020

Estimation of respiratory rate using infrared video in an inpatient population: an observational study.

Peter Chan, Gabriel Wong, Toan Dinh Nguyen, Tam Nguyen, John McNeil, Ingrid Hopper

Open access · bronzeAbstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in Journal of clinical monitoring and computing, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 2 pooled it
2.9field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 2 syntheses or guidelines pooled it, 23 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Review
  5. Review
  6. Article
  7. What is new in respiratory monitoring?Journal of clinical monitoring and computing · 2022
    Review
  8. Observational
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Peter ChanEastern Health Intensive Care Services, Eastern Health, Melbourne, Australia. Peter.chan@easternhealth.org.au.ORCID http://orcid.org/0000-0003-4578-9394
Gabriel WongEastern Health Intensive Care Services, Eastern Health, Melbourne, Australia.
Toan Dinh NguyenMonash eResearch Centre, Monash University, Melbourne, Australia.
Tam NguyenSt Vincent's Hospital, Melbourne, Australia.
John McNeilSchool of Public Health and Prevention Medicine, Monash University, Melbourne, Australia.
Ingrid HopperSchool of Public Health and Prevention Medicine, Monash University, Melbourne, Australia.
Eastern Health · AUMonash University · AUSt Vincent's Hospital Melbourne · AU

Funding

National Health and Medical Research Council GNT1168809
6 · The paper itself

Abstract

Respiratory rate (RR) is one of the most sensitive markers of a deteriorating patient. Despite this, there is significant inter-observer discrepancy when measured by clinical staff, and modalities used in clinical practice such as ECG bioimpedance are prone to error. This study utilized infrared thermography (IRT) to measure RR in a critically ill population in the Intensive Care Unit. This study was carried out in a Single Hospital Centre. Respiratory rate in 27 extubated ICU patients was counted by two observers and compared to ECG Bioimpedance and IRT-derived RR at distances of 0.4-0.6 m and > 1 m respectively. IRT-derived RR using two separate computer vision algorithms outperformed ECG derived RR at distances of 0.4-0.6 m. Using an Autocorrelation estimator, mean bias was - 0.667 breaths/min. Using a Fast Fourier Transform estimator, mean bias was - 1.000 breaths/min. At distances greater than 1 m no statistically significant signal could be obtained. Over all frequencies, there was a significant relationship between the RR estimated using IRT and via manual counting, with Pearson correlation coefficients between 0.796 and 0.943 (p < 0.001). Correlation between counting and ECG-derived RR demonstrated significance only at > 19 bpm (r = 0.562, p = 0.029). Overall agreement between IRT-derived RR at distances of 0.4-0.6 m and gold standard counting was satisfactory, and outperformed ECG derived bioimpedance. Contactless IRT derived RR may be feasible as a routine monitoring modality in wards and subacute inpatient settings.

Indexed as

InpatientsRespiratory RateAlgorithmsHumansSignal Processing, Computer-AssistedContactlessCritical careInfraredMonitoringRespiratory rate

Identifiers

PMID31792761
OpenAlexW2990623032

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.