Evidence map›Paper›PMID 31786953›Full record

ArticleJournal of diabetes science and technology2021

Sterilization of Drug-Loaded Composite Coatings for Implantable Glucose Biosensors.

Namita Tipnis, Michail Kastellorizios, Allen Legassey, Fotios Papadimitrakopoulos, Faquir Jain, Diane J Burgess

Abstract read
In one paragraph

Article in Journal of diabetes science and technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Namita TipnisDepartment of Pharmaceutical Sciences, University of Connecticut, Storrs, CT, USA.ORCID 0000-0003-3202-8465
Michail KastelloriziosBiorasis, Inc., UConn Technology Incubation Program, Storrs, CT, USA.
Allen LegasseyBiorasis, Inc., UConn Technology Incubation Program, Storrs, CT, USA.
Fotios PapadimitrakopoulosBiorasis, Inc., UConn Technology Incubation Program, Storrs, CT, USA.
Faquir JainBiorasis, Inc., UConn Technology Incubation Program, Storrs, CT, USA.
Diane J BurgessDepartment of Pharmaceutical Sciences, University of Connecticut, Storrs, CT, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAn anti-inflammatory drug-loaded composite coating (dexamethasone-loaded poly (lactic-co-glycolic acid) [PLGA] microspheres/polyvinyl alcohol [PVA] hydrogel) was previously developed to counter the foreign body reaction to a fully implantable continuous glucose monitoring biosensor. The long-term sensor functionality was ensured in the presence of the drug-loaded composite coating thus facilitating better diabetes control and management. In order to advance such a drug-device combination product toward clinical testing, addressing sterilization remains a key step due to the heterogeneity of the product components. The main objective of this research was to investigate the effect of two terminal sterilization techniques: gamma radiation and ethylene oxide (EO) on the stability of the anti-inflammatory coatings as well as retention of the glucose sensing ability of the implantable sensor.

methodThe composite coatings, their individual components, and the glucose-sensing elements of the biosensor were subjected to low-temperature gamma radiation and EO cycles. Detailed characterization was conducted on all components before and after sterilization.

resultsExposure to gamma radiation affected dexamethasone crystallinity and glucose response linearity of the sensing element, whereas physical aging of microspheres in composite coatings was observed poststerilization with EO. Despite these effects, dexamethasone drug release from coatings was not significantly affected by either technique.

conclusionThe research findings indicate that both sterilization techniques are feasible for the sterilization of the dexamethasone-loaded PLGA microspheres/PVA hydrogel composite coatings, while EO was preferred for the sterilization of the glucose-sensing element of the biosensor.

Indexed as

Biosensing TechniquesPharmaceutical PreparationsBlood GlucoseBlood Glucose Self-MonitoringDexamethasoneGlucoseHumansLactic AcidMicrospheresPolyglycolic AcidPolylactic Acid-Polyglycolic Acid CopolymerSterilizationBlood GlucoseDexamethasoneGlucoseLactic AcidPharmaceutical PreparationsPolyglycolic AcidPolylactic Acid-Polyglycolic Acid Copolymerdrug device combinationethylene oxidepolymeric implantable medical devicesradiationsterilization

Identifiers

PMID31786953
PMCPMC8120053

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.