Evidence map›Paper›PMID 31786683›Full record

ArticleSurgery today2020

Stapler sizes optimized for pancreatic thickness can reduce pancreatic fistula incidence after distal pancreatectomy.

Makoto Nishikawa, Junji Yamamoto, Mayumi Hoshikawa, Takahiro Einama, Takuji Noro, Suefumi Aosasa, Hironori Tsujimoto, Hideki Ueno, Yoji Kishi

Abstract read
PubMed Publisher
In one paragraph

Article in Surgery today, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.0field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 16 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Makoto NishikawaDepartment of Surgery, National Defense Medical College, Namiki 3-2, Tokorozawa, Saitama, 359-8513, Japan.
Junji YamamotoDepartment of Surgery, New Tokyo Hospital, Wanagaya 1271, Matsudo, Chiba, 270-2232, Japan. j-yamamoto@umin.ac.jp.
Mayumi HoshikawaDepartment of Surgery, New Tokyo Hospital, Wanagaya 1271, Matsudo, Chiba, 270-2232, Japan.
Takahiro EinamaDepartment of Surgery, National Defense Medical College, Namiki 3-2, Tokorozawa, Saitama, 359-8513, Japan.
Takuji NoroDepartment of Surgery, National Defense Medical College, Namiki 3-2, Tokorozawa, Saitama, 359-8513, Japan.
Suefumi AosasaDepartment of Surgery, National Defense Medical College, Namiki 3-2, Tokorozawa, Saitama, 359-8513, Japan.
Hironori TsujimotoDepartment of Surgery, National Defense Medical College, Namiki 3-2, Tokorozawa, Saitama, 359-8513, Japan.
Hideki UenoDepartment of Surgery, National Defense Medical College, Namiki 3-2, Tokorozawa, Saitama, 359-8513, Japan.
Yoji KishiDepartment of Surgery, National Defense Medical College, Namiki 3-2, Tokorozawa, Saitama, 359-8513, Japan.
National Defense Medical College · JPNew Tokyo Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this paper was to identify the optimum-sized stapler cartridges for reducing the incidence of postoperative pancreatic fistula (POPF) after distal pancreatectomy (DP).

methodsThe authors retrospectively analyzed 101 patients who underwent DP with a triple-row stapler to identify the clinicopathological factors that strongly influence POPF after DP. The height difference (HD) was defined as the difference between the pancreatic thickness and the height of the closed stapler.

resultsPOPF occurred in 58 (57%) patients. A multivariate analysis identified HD and pancreatic thickness as independent risk factors for the occurrence of POPF after DP. Akaike's information criterion for identifying the risk factors was more favorable for HD (115.18) than for pancreatic thickness (118.02). The incidence of POPF was significantly lower (29%) in patients with an HD between 6 and 12 mm than in the other two groups (< 6-mm group: 100%, P = 0.008; ≥ 12-mm group: 84%, P < 0.001).

conclusionsA too-thick or too-narrow pancreas carries a risk of developing POPF after DP when using a triple-row stapler. Selecting staplers to achieve an HD of 6-12 mm may reduce the incidence of POPF following DP.

Indexed as

Surgical StaplersAgedFemaleHumansMaleMiddle AgedMultivariate AnalysisPancreasPancreatectomyPancreatic FistulaPostoperative ComplicationsRiskDistal pancreatectomyPancreatic fistulaPancreatic thicknessStapler closure

Identifiers

PMID31786683
OpenAlexW2990543045

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.