Observational studyJournal of clinical anesthesia2020
Non-Invasive Venous waveform Analysis (NIVA) for monitoring blood loss in human blood donors and validation in a porcine hemorrhage model.
Observational study in Journal of clinical anesthesia, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 18 citations in OpenAlex.
- Non-invasive venous waveform analysis and the IntraVAscular volume Number (IVAN) track acute hemorrhage and volume overload in a piglet model.Research square · 2026Article
- Early detection of hypovolemia by venous pulse wave velocity and vena cava ultrasound imaging.European journal of applied physiology · 2026Article
- Invasive and Non-Invasive Remote Patient Monitoring Devices for Heart Failure: A Comparative Review of Technical Maturity and Clinical Readiness.Sensors (Basel, Switzerland) · 2025Review
- A prospective, observational study of non-invasive venous waveform analysis (NIVA) for the detection of acute low volume blood loss in humans.Journal of clinical anesthesia · 2025Observational
- A Porcine Model of Acute Respiratory Failure with a Continuous Infusion of Oleic Acid.Journal of visualized experiments : JoVE · 2024Article
- Evaluation of common clinical and hemodynamic parameters to pulmonary capillary wedge pressures in patients undergoing right heart catheterization.Medical research archives · 2023Article
- Article
- Noninvasive Venous Waveform Analysis Correlates With Pulmonary Capillary Wedge Pressure and Predicts 30-Day Admission in Patients With Heart Failure Undergoing Right Heart Catheterization.Journal of cardiac failure · 2022Article
- Respiratory Non-Invasive Venous Waveform Analysis for Assessment of Respiratory Distress in Coronavirus Disease 2019 Patients: An Observational Study.Critical care explorations · 2021Article
- Hemodynamic Parameters in the Assessment of Fluid Status in a Porcine Hemorrhage and Resuscitation Model.Anesthesiology · 2021Article
- Non-invasive venous waveform analysis (NIVA) for volume assessment in patients undergoing hemodialysis: an observational study.BMC nephrology · 2020Observational
- Article
- Physiology and clinical utility of the peripheral venous waveform.JRSM cardiovascular diseaseReview
- A brief report on the effects of vasoactive agents on peripheral venous waveforms in a porcine model.JRSM cardiovascular diseaseArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 1 institution in 1 country.
Funding
Abstract
STUDY
objectiveThere is an unmet need for a non-invasive approach to diagnose hemorrhage early, before changes in vital signs occur. Non-Invasive Venous waveform Analysis (NIVA) uses a unique physiological signal (the peripheral venous waveform) to assess intravascular volume. We hypothesized changes in the venous waveform would be observed with blood loss in healthy adult blood donors and characterized hemorrhage using invasive monitoring in a porcine model.
designProspective observational study.
settingAmerican Red Cross donation center. PATIENTS: 50 human blood donors and 12 non-donating controls; 7 Yorkshire pigs.
interventionsA venous waveform capturing prototype (NIVA device) was secured to the volar aspect of the wrist in human subjects. A central venous catheter was used to obtain hemodynamic indices and venous waveforms were obtained using the prototype NIVA device over the saphenous vein during 400 mL of graded hemorrhage in a porcine model. MEASUREMENTS: Venous waveforms were transformed from the time to the frequency domain. The ratiometric power contributions of the cardiac frequencies were used to calculate a NIVA value representative of volume status. MAIN
resultsA significant decrease in NIVA value was observed after 500 mL of whole blood donation (p < .05). A ROC curve for the ability of the NIVA to detect 500 mL of blood loss demonstrated an area under the curve (AUC) of 0.94. In the porcine model, change in NIVA value correlated linearly with blood loss and with changes in hemodynamic indices.
conclusionsThis study provides proof-of-concept for a potential application of NIVA in detection of blood loss. NIVA represents a novel physiologic signal for detection of early blood loss that may be useful in early triage and perioperative management.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.