Trial reportCanadian journal of surgery. Journal canadien de chirurgie2019
A double-blind randomized controlled trial of total knee replacement using patient-specific cutting block instrumentation versus standard instrumentation
Trial report in Canadian journal of surgery. Journal canadien de chirurgie, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03416946 (A Double-blinded, Randomized, Controlled Trial of Total Knee Replacement Using Custom Cutting Block Instrument vs Regular Instrumentation), which is not on this map. Cited by 8 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Double-blinded, Randomized, Controlled Trial of Total Knee Replacement Using Custom Cutting Block Instrument vs Regular Instrumentation
Who cites it
8 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Comparison of clinical outcomes of VISIONAIRE patient-specific instrumentation with conventional instrumentation in total knee arthroplasty: a systematic literature review and meta-analysis.Archives of orthopaedic and trauma surgery · 2023Pooled it
- A historical journey through total knee arthroplasty: the evolutionary milestones.International orthopaedics · 2026Review
- Comparison of the accuracy and efficacy of different assistive techniques in primary total knee arthroplasty: A network meta-analysis.Journal of experimental orthopaedics · 2024Article
- Global mapping of institutional and hospital-based (Level II-IV) arthroplasty registries: a scoping review.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2024Article
- Better forgotten joint scores when the angle of the prosthetic trochlea is lateral to the quadriceps vector in kinematically aligned total knee arthroplasty.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- Accuracy of a Three-Dimensional (3D)-Printed Patient-Specific (PS) Femoral Osteotomy Guide: A Computed Tomography (CT) Study.Bioengineering (Basel, Switzerland) · 2022Article
- Innovations in Shoulder Arthroplasty.Journal of clinical medicine · 2022Review
- Accurate implant fit and leg alignment after cruciate-retaining patient-specific total knee arthroplasty.BMC musculoskeletal disorders · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Patient-specific cutting blocks in total knee arthroplasty have been promoted to improve mechanical alignment, reduce alignment outliers and improve patient outcomes. The aim of this study was to compare the efficacy of patient-specific instrumentation (PSI) and conventional instrumentation (CI) in achieving neutral alignment and accurate component positioning in total knee arthroplasty. Methods: We conducted a double-blinded randomized controlled trial in which patients were randomly assigned to treatment with either PSI or CI. Results: Fifty-four patients were included in the study. No relevant improvement in coronal alignment was found between the PSI and CI groups with post-hoc power of 0.91. Tibial slope was found to be more accurately reproduced to the preoperative target of 3° with PSI than with CI (3.8°± 3.1° v. 7.7°± 3.6°, respectively, p < 0.001). There were no differences found in patient-reported outcome measures, surgical time or length of hospital stay. Conclusion: Given the added cost of the PSI technique, its use is difficult to justify given the small improvement in only a single alignment parameter. Clinical trial registration: Clinicaltrials.gov, no. NCT03416946
Indexed as
Identifiers
What OpenQuestion holds
Registered trials