Observational studyFrontiers in immunology2019
Free Radical Production, Inflammation and Apoptosis in Patients Treated With Titanium Mandibular Fixations-An Observational Study.
Observational study in Frontiers in immunology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
32 citing papers in PubMed, 55 citations in OpenAlex.
- The Correlation of Enhanced Osteogenic Capability in Titanium Alloy Implants Through Modulation of the Runx2/BSP Pathway.Journal of cellular and molecular medicine · 2026Article
- Beyond the germ: Rethinking implant-related infections as a host-microbiota-biomaterial ecosystem.Biofilm · 2026Review
- Suspected Hypersensitivity Reaction to Titanium Screws Following Kalish Osteotomy for Hallux Valgus.Cureus · 2026Article
- Assessment of Radiographic Image Texture in the Maxilla and Mandible Around Titanium Inserts Used for Osteosynthesis of Dentofacial Deformities.Journal of functional biomaterials · 2025Article
- In Vivo Investigation on the Effects of Metal Oxides in Hydroxyapatite Biocomposite Implants for Improving Bone Regeneration.Biological trace element research · 2025Article
- Synergistic exacerbation of periprosthetic osteolysis by inflammatory bowel disease and titanium ions: Impaired osteogenesis of BMSCs via PI3K/AKT signaling.Materials today. Bio · 2025Article
- Clinical practice guidelines for postoperative pain management in adults (2024 edition).Journal of anesthesia and translational medicine · 2025Review
- Profile of the Main Representatives of Sphingolipid Metabolism in the Maxillary and Mandibular Periosteum of Patients with Dentofacial Deformities After Osteosynthesis Using Titanium Implants.Journal of clinical medicine · 2025Article
- The Pattern of Cytokines, Chemokines, and Growth Factors of the Maxillary and Mandibular Periosteum After Exposure to Titanium Fixations-Ti6Al4V.Journal of clinical medicine · 2024Article
- Titanium nanoparticles released from orthopedic implants induce muscle fibrosis via activation of SNAI2.Journal of nanobiotechnology · 2024Article
- Evaluation of the effect of intraoperative tropisetron on postoperative rebound pain after brachial plexus block: a randomized controlled trial.Pain reports · 2024Article
- A PEEK into carbon fiber: A practical guide for high performance composite polymeric implants for orthopaedic oncology.Journal of orthopaedics · 2023Article
- Review
- Mitochondrial Redox Balance of Fibroblasts Exposed to Ti-6Al-4V Microplates Subjected to Different Types of Anodizing.International journal of molecular sciences · 2023Article
- Which of 51 Plate Designs Can Most Stably Fixate the Fragments in a Fracture of the Mandibular Condyle Base?Journal of clinical medicine · 2023Article
- The role of mitochondria in the peri-implant microenvironment.Experimental physiology · 2023Review
- The Role of the Assembly Force in the Tribocorrosion Behaviour of Hip Implant Head-Neck Junctions: An Adaptive Finite Element Approach.Bioengineering (Basel, Switzerland) · 2022Article
- Quantitative imaging of apoptosis following oncolytic virotherapy by magnetic resonance fingerprinting aided by deep learning.Nature biomedical engineering · 2022Article
- Bone Union Quality after Fracture Fixation of Mandibular Head with Compression Magnesium Screws.Materials (Basel, Switzerland) · 2022Article
- Clinical Evaluation of Magnesium Alloy Osteosynthesis in the Mandibular Head.Materials (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Despite high biocompatibility of titanium and its alloys, this metal causes various side effects in the human body. It is believed that titanium biomaterials may induce an innate/adaptive immune response. However, still little is known about changes caused by titanium mandible implants, particularly with regard to bone healing. The latest studies showed disturbances in the antioxidant barrier, increased oxidative/nitrosative stress, as well as mitochondrial abnormalities in the periosteum covering titanium mandible fixations; nevertheless, the impact of titanium implants on free radical production, inflammation, and mandible apoptosis are still unknown. Because severe inflammation and apoptosis are among the main factors responsible for disturbances in osteointegration as well as implant rejection, this study is the first to evaluate pro-oxidant enzymes, cytokines as well as pro- and anti-apoptotic proteins in the periosteum of patients with a broken jaw, treated with titanium miniplates and miniscrews. The study group consisted of 29 patients with double-sided fracture of the mandible body requiring surgical treatment. We found significantly higher activity of NADPH oxidase and xanthine oxidase as well as enhanced rate of free radical production in the periosteum of patients in the study group compared to the control group. The markers of inflammation [interleukin 1 (IL-1), interleukin 6 (IL-6), tumor necrosis factor α (TNF-α), transforming growth factor β (TGF-β) and β-glucuronidase (GLU)] as well as apoptosis [Bax, Bax/Bcl-2 ratio, caspase-3 (CAS-3) and nitric oxide (NO)] were significantly elevated in periosteum covering titanium fixations compared to the control group. In the study group, we also demonstrated an increased content of titanium on the periosteum surface, which positively correlated with CAS-3 activity. The study led us to the conclusion that titanium mandible implants increase the production of pro-inflammatory cytokines, and enhance free radical generation in the periosteum covering titanium miniplates and miniscrews. Additionally, exposure to Ti6Al4V titanium alloy induces apoptosis in the mandible periosteum. However, no clinical signs of the said phenomena have been observed.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.