ArticleScientific reports2019
Image quality comparison between a phase-contrast synchrotron radiation breast CT and a clinical breast CT: a phantom based study.
Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 43 citations in OpenAlex.
- An integrated digital-to-surgical framework for patient-specific chest wall resection and reconstruction using 3D-printed titanium implants: proof-of-concept study.npj biomedical innovations · 2026Article
- Radiomic Characterization of Breast Tissue from Breast CT Images Obtained with Synchrotron Beams.Tomography (Ann Arbor, Mich.) · 2026Article
- The Use of Synchrotron Radiation in the Medical Sciences.Photon science · 2026Article
- Low-dose, high-resolution CT of infant-sized lungs via propagation-based phase contrast.Scientific reports · 2025Article
- Comparative image quality and dosimetric performance of two generations of dedicated breast CT systems.Medical physics · 2025Article
- Signal-to-noise and spatial resolution in in-line imaging. 1. Basic theory, numerical simulations and planar experimental images.Journal of synchrotron radiation · 2024Article
- Enhancing Radiological Diagnosis: A Comprehensive Review of Image Quality Assessment and Optimization Strategies.Cureus · 2024Review
- Article
- Volumetric High-Resolution X-Ray Phase-Contrast Virtual Histology of Breast Specimens With a Compact Laboratory System.IEEE transactions on medical imaging · 2022Article
- Dedicated breast CT: state of the art-Part II. Clinical application and future outlook.European radiology · 2022Review
- Motion artifacts assessment and correction using optical tracking in synchrotron radiation breast CT.Medical physics · 2021Article
- A quality optimization approach to image Achilles tendon microstructure by phase-contrast enhanced synchrotron micro-tomography.Scientific reports · 2021Article
- Development and preclinical evaluation of a patient-specific high energy x-ray phase sensitive breast tomosynthesis system.Medical physics · 2021Article
- A phantom study to contrast and compare polymer and gold fiducial markers in radiotherapy simulation imaging.Scientific reports · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors at 6 institutions in 2 countries.
Funding
Abstract
In this study we compared the image quality of a synchrotron radiation (SR) breast computed tomography (BCT) system with a clinical BCT in terms of contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), noise power spectrum (NPS), spatial resolution and detail visibility. A breast phantom consisting of several slabs of breast-adipose equivalent material with different embedded targets (i.e., masses, fibers and calcifications) was used. Phantom images were acquired using a dedicated BCT system installed at the Radboud University Medical Center (Nijmegen, The Netherlands) and the SR BCT system at the SYRMEP beamline of Elettra SR facility (Trieste, Italy) based on a photon-counting detector. Images with the SR setup were acquired mimicking the clinical BCT conditions (i.e., energy of 30 keV and radiation dose of 6.5 mGy). Images were reconstructed with an isotropic cubic voxel of 273 µm for the clinical BCT, while for the SR setup two phase-retrieval (PhR) kernels (referred to as "smooth" and "sharp") were alternatively applied to each projection before tomographic reconstruction, with voxel size of 57 × 57 × 50 µm