Evidence map›Paper›PMID 31780707›Full record

ArticleScientific reports2019

Image quality comparison between a phase-contrast synchrotron radiation breast CT and a clinical breast CT: a phantom based study.

Luca Brombal, Fulvia Arfelli, Pasquale Delogu, Sandro Donato, Giovanni Mettivier, Koen Michielsen, Piernicola Oliva, Angelo Taibi, Ioannis Sechopoulos, Renata Longo and 1 more

Open access · goldAbstract readComparative Study
In one paragraph

Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
6.6field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 43 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 6 institutions in 2 countries.

Luca BrombalDepartment of Physics, University of Trieste, 34127, Trieste, Italy.ORCID http://orcid.org/0000-0002-4009-8191
Fulvia ArfelliDepartment of Physics, University of Trieste, 34127, Trieste, Italy.
Pasquale DeloguDepartment of Physical Sciences, Earth and Environment, University of Siena, 53100, Siena, Italy.ORCID http://orcid.org/0000-0003-2026-2000
Sandro DonatoDepartment of Physics, University of Trieste, 34127, Trieste, Italy.
Giovanni MettivierDepartment of Physics, University of Napoli Federico II, 80126, Fuorigrotta Napoli, Italy.ORCID http://orcid.org/0000-0001-6606-4304
Koen MichielsenDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, 6500 HB, Nijmegen, The Netherlands.
Piernicola OlivaDepartment of Chemistry and Pharmacy, University of Sassari, 07100, Sassari, Italy.ORCID http://orcid.org/0000-0002-9446-3967
Angelo TaibiDepartment of Physics and Earth Science, University of Ferrara, 44122, Ferrara, Italy.
Ioannis SechopoulosDepartment of Radiology and Nuclear Medicine, Radboud University Medical Center, 6500 HB, Nijmegen, The Netherlands.
Renata LongoDepartment of Physics, University of Trieste, 34127, Trieste, Italy. renata.longo@infn.ts.it.
Christian FedonINFN Division of Trieste, 34127, Trieste, Italy.ORCID http://orcid.org/0000-0002-5998-453X
University of Trieste · ITRadboud University Nijmegen · NLIstituto Nazionale di Fisica Nucleare, Sezione di Napoli · ITUniversity of Ferrara · ITUniversity of Sassari · ITUniversity of Siena · IT

Funding

Image Quality Improvement and Performance Assessment of Dedicated Breast CTR01CA181171 · NCI · STICHTING RADBOUD UNIVERSITAIR MEDISCH CENTRUM I.O. · PI SECHOPOULOS, IOANNIS · 2015 to 2020
$1.1M
NCI NIH HHS R01 CA181171
6 · The paper itself

Abstract

In this study we compared the image quality of a synchrotron radiation (SR) breast computed tomography (BCT) system with a clinical BCT in terms of contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), noise power spectrum (NPS), spatial resolution and detail visibility. A breast phantom consisting of several slabs of breast-adipose equivalent material with different embedded targets (i.e., masses, fibers and calcifications) was used. Phantom images were acquired using a dedicated BCT system installed at the Radboud University Medical Center (Nijmegen, The Netherlands) and the SR BCT system at the SYRMEP beamline of Elettra SR facility (Trieste, Italy) based on a photon-counting detector. Images with the SR setup were acquired mimicking the clinical BCT conditions (i.e., energy of 30 keV and radiation dose of 6.5 mGy). Images were reconstructed with an isotropic cubic voxel of 273 µm for the clinical BCT, while for the SR setup two phase-retrieval (PhR) kernels (referred to as "smooth" and "sharp") were alternatively applied to each projection before tomographic reconstruction, with voxel size of 57 × 57 × 50 µm

Indexed as

AlgorithmsBreastBreast NeoplasmsFemaleHumansMammographyPhantoms, ImagingSignal-To-Noise RatioSynchrotronsTomography, X-Ray Computed

Identifiers

PMID31780707
PMCPMC6882794
OpenAlexW2990187846

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.