ArticleSensors (Basel, Switzerland)2019
A Reference Matching-Based Temperature Compensation Method for Ultrasonic Guided Wave Signals.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Driver Head-Hand Cooperative Action Recognition Based on FMCW Millimeter-Wave Radar and Deep Learning.Sensors (Basel, Switzerland) · 2025Article
- A Novel Temperature Drift Compensation Algorithm for Liquid-Level Measurement Systems.Micromachines · 2024Article
- Review of Current Guided Wave Ultrasonic Testing (GWUT) Limitations and Future Directions.Sensors (Basel, Switzerland) · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
The ultrasonic guided wave-based structural damage diagnosis method has broad application prospects in different fields. However, some environmental factors such as temperature and loads will significantly affect the monitoring results. In this paper, a reference matching-based temperature compensation for ultrasonic guided wave signals is proposed to eliminate the effect of temperature. Firstly, the guided wave signals measured at different temperatures are used as reference signals to establish the relationship between the features of the reference signals and temperature. Then the matching algorithm based on Gabor function is used to establish the relationship between the amplitude influence coefficient obtained by the reference signal and the corresponding temperature. Finally, through these two relationships, the values of the phase and amplitude influence coefficients of the guided wave signals at other temperatures are obtained in a way of interpolation in order to reconstruct the compensation signals at the temperature. The effect of temperature on the amplitude and phase of the guided wave signal is eliminated. The proposed temperature compensation method is featured such that the compensation performance can be improved by multiple iteration compensation of the residual signal. The ultrasonic guided wave test results at different temperatures show that the first iterative compensation of the proposed method can achieve compensation within the temperature range greater than 7 °C, and the compensation within the temperature range greater than 18 °C can be achieved after three iterations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.