Evidence map›Paper›PMID 31778366›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2019

Comparison of Inspiratory Effort, Workload and Cycling Synchronization Between Non-Invasive Proportional-Assist Ventilation and Pressure-Support Ventilation Using Different Models of Respiratory Mechanics.

Yuqing Chen, Yueyang Yuan, Hai Zhang, Feng Li

Open access · hybridAbstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 6 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Yuqing ChenDepartment of Respiratory Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China (mainland).
Yueyang YuanSchool of Mechanical and Electrical Engineering, Hu Nan City University, Yi Yang, Hunan, China (mainland).
Hai ZhangDepartment of Respiratory Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China (mainland).
Feng LiDepartment of Respiratory Medicine, Shanghai Chest Hospital, Shanghai Jiao Tong University, Shanghai, China (mainland).
Shanghai Jiao Tong University · CNHunan City University · CNShanghai Chest Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND This study assessed lung models for the influence of respiratory mechanics and inspiratory effort on breathing pattern and simulator-ventilator cycling synchronization in non-invasive ventilation. MATERIAL AND METHODS A Respironics V60 ventilator was connected to an active lung simulator modeling mildly restrictive, severely restrictive, obstructive and mixed obstructive/restrictive profiles. Pressure-support ventilation (PSV) and proportional-assist ventilation (PAV) were set to obtain similar tidal volume (VT). PAV was applied at flow assist (FA) 40-90% of resistance (Rrs) and volume assist (VA) 40-90% of elastance (Ers). Measurements were performed with system air leak of 25-28 L/minute. Ventilator performance and simulator-ventilator asynchrony were evaluated. RESULTS At comparable VT, PAV had slightly lower peak inspiratory flow and higher driving pressure compared with PSV. Premature cycling occurred in the obstructive, severely restrictive and mildly restrictive models. During PAV, time for airway pressure to achieve 90% of maximum during inspiration (T90) in the severely restrictive model was shorter than those of the obstructive and mixed obstructive/restrictive models and close to that measured in the PSV mode. Increasing FA level reduced inspiratory trigger workload (PTP₃₀₀) in obstructive and mixed obstructive/restrictive models. Increasing FA level decreased inspiratory time (TI) and tended to aggravate premature cycling, whereas increasing VA level attenuated this effect. CONCLUSIONS PAV with an appropriate combination of FA and VA decreases work of breathing during the inspiratory phase and improves simulator-ventilator cycling synchrony. FA has greater impact than VA in the adaptation to inspiratory effort demand. High VA level might help improve cycling synchrony.

Indexed as

ChinaHumansModels, AnatomicPositive-Pressure RespirationRespirationRespiration, ArtificialRespiratory Function TestsRespiratory MechanicsTidal VolumeVentilators, Mechanical

Identifiers

PMID31778366
PMCPMC6900923
OpenAlexW2990484168

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.