Trial reportScientific reports2019
Radiation Exposure of Patient and Operating Room Personnel by Fluoroscopy and Navigation during Spinal Surgery.
Trial report in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 59 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
59 citing papers in PubMed, 2 syntheses or guidelines pooled it, 99 citations in OpenAlex.
- Is Ocular Safety in Orthopaedics Overlooked? A Systematic Review of Annual Ocular Radiation Exposure and Protective Measures.Clinical orthopaedics and related research · 2024Pooled it
- Cervical Spine Pedicle Screw Accuracy in Fluoroscopic, Navigated and Template Guided Systems-A Systematic Review.Tomography (Ann Arbor, Mich.) · 2021Pooled it
- Clinical and radiological evaluation of cortical bone trajectory screw placement using patient-specific 3D templates: a multicentric prospective study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- [Computer-assisted spine surgery : Current status and future perspectives].Orthopadie (Heidelberg, Germany) · 2026Review
- Redefining the applications of navigation in spine surgery.Neurosurgical focus: Video · 2026Article
- Real-time phase-dependent occupational radiation exposure analysis in full-endoscopic spine surgery.Scientific reports · 2026Article
- Radiation Exposure in Robotic-Assisted Versus Conventional and Navigation-Assisted Spine Surgery: A Systematic Review, Meta-Analysis, and Meta-Regression of 3205 Patients.Journal of clinical medicine · 2026Review
- Intraoperative Navigation in Cervical Spine Surgery.Journal of clinical medicine · 2026Review
- Evaluation of the stray radiation distribution around a mobile cone beam computed tomography system in a simulated operating room environment.Journal of applied clinical medical physics · 2026Article
- An innovative 2D optical navigation workflow for percutaneous pedicle screw fixation in thoracolumbar fractures: comparison with O-arm 3D navigation.Frontiers in surgery · 2026Article
- Accuracy, safety, and functional outcomes of O-arm navigation-guided posterior cervical spine fixation: An ambispective cohort of 147 screws.Surgical neurology international · 2026Article
- Towards a radiation-free clinical decision support system for intraoperative spinal alignment assessment.Medical & biological engineering & computing · 2025Article
- Radiation Protection Compliance in Fluoroscopy-Assisted Procedures: A Prospective Audit in Operating Theatres.Cureus · 2025Article
- Free-Hand Pedicle Screw Placement Using a Ball Tip Widening Technique for Small Pedicles.Clinics in orthopedic surgery · 2025Article
- The anterior intercrest line is a novel, accurate surface marking for identifying the L4/5 disc level: a prospective agreement study with fluoroscopy.North American Spine Society journal · 2025Article
- Prediction of screw loosening by measuring the insertion torque in non-osteoporotic patients: an in vitro study.BMC musculoskeletal disorders · 2025Article
- Imaging of scattered radiation sources in X-ray radiography using a semiconductor radiation visualization camera.Radiological physics and technology · 2025Article
- The application of ultrasound-guided cannulated screw removal after proximal tibial fracture surgery: a retrospective study.Frontiers in pediatrics · 2025Article
- Novel anatomical landmark guided puncture method in L4/L5 spine posterior interlaminar endoscopic surgery: a technical note and case series.Frontiers in surgery · 2025Article
- Current state and future perspectives of spinal navigation and robotics-an AO spine survey.Brain & spine · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intraoperative radiography imaging is essential for accurate spinal implant placement. Hazards caused by ionizing radiation raised concern on personnel's work life long exposure in the operating room (OR). To particularize a cumulative risk estimation of radiation of personnel and patient, depending on used methods (C-arm fluoroscopy, O-arm navigation) and patient characteristics during spinal surgery, detailed investigation of radiation exposure in a clinical setting is required. Lumbosacral dorsal spinal fusion was performed in 37 patients (19 navigated, 18 fluoroscopy) during this prospective study. Radiation exposure was measured on several body regions with thermoluminescent dosimeters on patient and OR personnel (surgeon, assistant, sterile nurse, radiology technologist). Comparison between patient characteristics and radiation exposure was included. The highest patients values were measured in the surgery field and gonads area during navigation (43.2 ± 19.4 mSv; fluoroscopy: 27.7 ± 31.3 mSv; p = 0.02), followed by the thoracic region during fluoroscopy (7.7 ± 14.8 mSv; navigation: 1.1 ± 1.0 mSv; p = 0.06), other measured regions can be considered marginal in comparison. Amongst OR personnel exposure of the surgeon was significant higher during fluoroscopy (right hand: 566 ± 560 µSv and thoracic region: 275 ± 147 µSv; followed by thyroid and forehead) compared to navigation (right finger: 49 ± 19 µSv; similar levels for all regions; p < 0.001 in all regions). When compared to the surgeon, other OR personnel had significantly lower radiation doses on all body regions using fluoroscopy, and similar dose during navigation. The highest eye's lens region value was measured during fluoroscopy for the patient (185 ± 165 µSv; navigation: 205 ± 60 µSv; p = 0.57) and the surgeon (164 ± 74 µSv; navigation: 92 ± 41 µSv; p < 0.001). There was a significant correlation between patient BMI and radiation exposure to the surgery field during fluoroscopy. To our knowledge, these data present the first real life, detailed comparison of radiation exposure on OR personnel and patients between clinical use of navigation and fluoroscopy. Although patient's radiation dose is approximately 3-fold during navigation compared to the fluoroscopy, we found that a spinal surgeon could perform up to 10-fold number of surgeries (10.000 versus 883) until maximum permissible annual effective radiation dose would be reached. Especially for a spinal surgeon, who is mainly exposed amongst OR personnel, radiation prevention and protection must remain a main issue.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.