Evidence map›Paper›PMID 31776364›Full record

Trial reportScientific reports2019

Radiation Exposure of Patient and Operating Room Personnel by Fluoroscopy and Navigation during Spinal Surgery.

G Bratschitsch, L Leitner, G Stücklschweiger, H Guss, P Sadoghi, P Puchwein, A Leithner, R Radl

Open access · goldAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 59 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
59citing papers in PubMed, 2 pooled it
6.5field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

59 citing papers in PubMed, 2 syntheses or guidelines pooled it, 99 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Clinical and radiological evaluation of cortical bone trajectory screw placement using patient-specific 3D templates: a multicentric prospective study.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026
    Article
  4. Review
  5. Article
  6. Article
  7. Review
  8. Intraoperative Navigation in Cervical Spine Surgery.Journal of clinical medicine · 2026
    Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

G BratschitschDepartment of Orthopedics and Trauma, Medical University of Graz, Graz, Austria.
L LeitnerDepartment of Orthopedics and Trauma, Medical University of Graz, Graz, Austria.
G StücklschweigerCompetence Center for Medical Physics and Radiation Protection, Medical University of Graz, Graz, Austria.
H GussCompetence Center for Medical Physics and Radiation Protection, Medical University of Graz, Graz, Austria.
P SadoghiDepartment of Orthopedics and Trauma, Medical University of Graz, Graz, Austria. patrick.sadoghi@medunigraz.at.
P PuchweinDepartment of Orthopedics and Trauma, Medical University of Graz, Graz, Austria.
A LeithnerDepartment of Orthopedics and Trauma, Medical University of Graz, Graz, Austria.
R RadlDepartment of Orthopedics and Trauma, Medical University of Graz, Graz, Austria.
Medical University of Graz · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Intraoperative radiography imaging is essential for accurate spinal implant placement. Hazards caused by ionizing radiation raised concern on personnel's work life long exposure in the operating room (OR). To particularize a cumulative risk estimation of radiation of personnel and patient, depending on used methods (C-arm fluoroscopy, O-arm navigation) and patient characteristics during spinal surgery, detailed investigation of radiation exposure in a clinical setting is required. Lumbosacral dorsal spinal fusion was performed in 37 patients (19 navigated, 18 fluoroscopy) during this prospective study. Radiation exposure was measured on several body regions with thermoluminescent dosimeters on patient and OR personnel (surgeon, assistant, sterile nurse, radiology technologist). Comparison between patient characteristics and radiation exposure was included. The highest patients values were measured in the surgery field and gonads area during navigation (43.2 ± 19.4 mSv; fluoroscopy: 27.7 ± 31.3 mSv; p = 0.02), followed by the thoracic region during fluoroscopy (7.7 ± 14.8 mSv; navigation: 1.1 ± 1.0 mSv; p = 0.06), other measured regions can be considered marginal in comparison. Amongst OR personnel exposure of the surgeon was significant higher during fluoroscopy (right hand: 566 ± 560 µSv and thoracic region: 275 ± 147 µSv; followed by thyroid and forehead) compared to navigation (right finger: 49 ± 19 µSv; similar levels for all regions; p < 0.001 in all regions). When compared to the surgeon, other OR personnel had significantly lower radiation doses on all body regions using fluoroscopy, and similar dose during navigation. The highest eye's lens region value was measured during fluoroscopy for the patient (185 ± 165 µSv; navigation: 205 ± 60 µSv; p = 0.57) and the surgeon (164 ± 74 µSv; navigation: 92 ± 41 µSv; p < 0.001). There was a significant correlation between patient BMI and radiation exposure to the surgery field during fluoroscopy. To our knowledge, these data present the first real life, detailed comparison of radiation exposure on OR personnel and patients between clinical use of navigation and fluoroscopy. Although patient's radiation dose is approximately 3-fold during navigation compared to the fluoroscopy, we found that a spinal surgeon could perform up to 10-fold number of surgeries (10.000 versus 883) until maximum permissible annual effective radiation dose would be reached. Especially for a spinal surgeon, who is mainly exposed amongst OR personnel, radiation prevention and protection must remain a main issue.

Indexed as

Intraoperative PeriodFluoroscopyHumansOccupational ExposureOperating RoomsProspective StudiesRadiation DosageRadiation ExposureSpineSurgeonsSurgery, Computer-Assisted

Identifiers

PMID31776364
PMCPMC6881318
OpenAlexW2990010836

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.