Evidence map›Paper›PMID 31772527›Full record

ArticleJournal of interventional cardiology2019

Clinical and Technical Characteristics of Coronary Angiography and Percutaneous Coronary Interventions Performed before and after Transcatheter Aortic Valve Replacement with a Balloon-Expandable Valve.

Alfredo Nunes Ferreira-Neto, Rishi Puri, Lluis Asmarats, Victoria Vilalta, Leonardo Guimaraes, Robert Delarochellière, Jean-Michel Paradis, Siamak Mohammadi, Eric Dumont, Josep Rodés-Cabau

Open access · goldAbstract read
In one paragraph

Article in Journal of interventional cardiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.4field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 23 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Coronary artery cannulation after transcatheter aortic valve implantation.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2021
    Review
  6. Article
  7. Review
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Alfredo Nunes Ferreira-NetoQuebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada.ORCID https://orcid.org/0000-0003-4420-7743
Rishi PuriQuebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada.
Lluis AsmaratsQuebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada.
Victoria VilaltaQuebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada.
Leonardo GuimaraesQuebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada.
Robert DelarochellièreQuebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada.
Jean-Michel ParadisQuebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada.
Siamak MohammadiQuebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada.
Eric DumontQuebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada.
Josep Rodés-CabauQuebec Heart & Lung Institute, Laval University, Quebec City, Quebec, Canada.ORCID https://orcid.org/0000-0001-8237-7095
Université Laval · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo report on the feasibility and technical differences between coronary procedures performed before and after TAVR with the balloon-expandable Edwards-SAPIEN or the SAPIEN XT valves.

backgroundCoronary artery disease (CAD) and aortic stenosis often coexist. Transcatheter aortic valve replacement (TAVR) is emerging as a treatment for younger and lower surgical risk patients who might not present with clinically evident CAD before TAVR. The demand for performing post-TAVR coronary angiograms (CAs) and percutaneous coronary interventions (PCIs) will thus increase, posing new technical challenges.

methodsOver 1000 TAVRs were performed at the Quebec Heart and Lung Institute, of which 616 with the abovementioned valves. Of these, 28 patients had an analyzable pre- and post-TAVR CAs and 13 patients had pre- and post-TAVR PCIs performed. Procedural characteristics were gathered from all coronary procedures and subsequently compared amongst the same type of procedure performed at these two distinct time periods.

resultsNeither CAs-nor PCIs-performed after valve implantation revealed significant differences regarding arterial access site, catheter diameter, number of diagnostic or guiding catheters used, procedural duration, fluoroscopy time, or achievement of selective coronary injection. Lesion location and classification, as well as the preference of using a drug-eluting stent, remained unchanged. During post-TAVR CA, the amount of contrast delivered and the radiation dose area product were significantly lower compared with pre-TAVR CA values.

conclusionsPerformance of CA and PCI after TAVR with a balloon-expandable valve appears unaffected by its presence.

Indexed as

Balloon ValvuloplastyCoronary AngiographyPercutaneous Coronary InterventionTranscatheter Aortic Valve ReplacementAgedAortic ValveContrast MediaFeasibility StudiesFemaleHeart Valve ProsthesisHumansMaleRadiation DosageContrast Media

Identifiers

PMID31772527
PMCPMC6738988
OpenAlexW2967717934

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.