Evidence map›Paper›PMID 31772380›Full record

SynthesisEye (London, England)2020

Intra-operative optical coherence tomography in glaucoma surgery-a systematic review.

Bryan C H Ang, Sheng Yang Lim, Syril Dorairaj

Open access · bronzeAbstract readSystematic Review
In one paragraph

Synthesis in Eye (London, England), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed, 2 pooled it
2.2field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 2 syntheses or guidelines pooled it, 32 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Observational
  4. Medical image registration and its application in retinal images: a review.Visual computing for industry, biomedicine, and art · 2024
    Review
  5. Article
  6. Recent Advancements in Glaucoma Surgery-A Review.Bioengineering (Basel, Switzerland) · 2023
    Review
  7. Review
  8. Article
  9. Optical Coherence Tomography and Glaucoma.Annual review of vision science · 2021
    Review
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 2 countries.

Bryan C H Ang *Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore, Singapore.
Sheng Yang Lim *Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore.ORCID http://orcid.org/0000-0002-4463-4932
Syril DorairajDepartment of Ophthalmology, Mayo Clinic, Jacksonville, Florida, USA. dorairaj.syril@mayo.edu.
Jacksonville College · USNational University of Singapore · SGTan Tock Seng Hospital · SG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The application of the OCT in clinical ophthalmology has expanded significantly since its introduction more than 20 years ago. There has been recent growing interest in the application of intra-operative optical coherence tomography (iOCT). The iOCT's ability to enhance visualisation and depth appreciation has the potential to be further exploited in glaucoma surgery, especially with the emergence of Minimally Invasive Glaucoma Surgery (MIGS)-to facilitate targeted device placement and fine surgical manoeuvres in the angles, the sub-conjunctival layer and the suprachoroidal space. Hence, this study aims to appraise the current literature on the applications of iOCT in glaucoma surgery. A total of 79 studies were identified following a literature search adhering to PRISMA guidelines. After full text evaluation, 10 studies discussing iOCT use in glaucoma surgery were included. Traditional glaucoma filtering procedures reviewed included trabeculectomy surgery, goniosynechiolysis, bleb needling and glaucoma drainage device implantation. MIGS procedures reviewed included canaloplasty, trabecular aspiration, ab-interno trabectome and the XEN45 gel stent. iOCT use in ophthalmic surgery is becoming increasingly prevalent and has already been applied in various surgeries and procedures in the field of glaucoma. With the greater adoption of MIGS, iOCT may further contribute in facilitating surgical techniques and improving outcomes. While iOCT offers many advantages, there are still limitations to be overcome-iOCT technology continues to evolve to optimise imaging quality and user-experience.

Indexed as

GlaucomaGlaucoma Drainage ImplantsOphthalmologyHumansIntraocular PressureTomography, Optical Coherence

Identifiers

PMID31772380
PMCPMC7002696
OpenAlexW2991461381

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.