Digital postpartum hemorrhage management device (DPHMD).

Derartu D Tekela, Abeba G Asmare, Birhan M Gebremariam, Christian A Assegahegn, Kidist D Wami, Hundessa D Nemomssa, Gizeaddis L Simegn

Open access · goldAbstract read
In one paragraph

Article in BMC pregnancy and childbirth, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.8field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 8 citations in OpenAlex.

  1. Two Zn(II)-based Coordination Polymers: FeJournal of fluorescence · 2020
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Derartu D TekelaSchool of Biomedical Engineering, Jimma Institute of Technology, Jimma University, Jimma, Ethiopia.
Abeba G AsmareSchool of Biomedical Engineering, Jimma Institute of Technology, Jimma University, Jimma, Ethiopia.
Birhan M GebremariamSchool of Biomedical Engineering, Jimma Institute of Technology, Jimma University, Jimma, Ethiopia.
Christian A AssegahegnSchool of Biomedical Engineering, Jimma Institute of Technology, Jimma University, Jimma, Ethiopia.
Kidist D WamiSchool of Biomedical Engineering, Jimma Institute of Technology, Jimma University, Jimma, Ethiopia.
Hundessa D NemomssaSchool of Biomedical Engineering, Jimma Institute of Technology, Jimma University, Jimma, Ethiopia.
Gizeaddis L SimegnSchool of Biomedical Engineering, Jimma Institute of Technology, Jimma University, Jimma, Ethiopia. 1time.et@gmail.com.
Jimma University · ET

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPrimary postpartum hemorrhage (PPH) is an obstetric emergency caused by excessive blood loss that occurs most commonly after the placenta is delivered. PPH can lead to volume depletion, hypovolemic shock, anemia, and it is the leading cause of maternal mortality worldwide. With 470 deaths per 100,000 live births, the maternal mortality ratio in Ethiopia is one of the highest in the world. It is estimated that 94% of births occur at home in Ethiopia and that 10% of maternal deaths are attributed to PPH. Currently, physicians use visual estimation to calculate blood loss and provide fluid during delivery. This traditional method is subjective and generally inaccurate.

methodIn this project, after delivery blood loss measurement system integrated with fluid delivery and vital sign monitoring method is proposed. The collection and measurement system collects blood loss after delivery and measures the amount of blood loss. The management system continuously monitors the mother's heart rate and blood pressure. These vital sign values are integrated with the measured blood loss to estimate the amount of IV fluid required to be delivered for the mother. The rate of IV fluid delivery is regulated by a flow rate sensor and solenoid valve.

resultsThe prototype was built and undergone through different tests and iterations. The proposed device was tested for accuracy, cost effectiveness and ease to use. 91.28% accuracy has been achieved and the prototype was built with less than 210 USD.

conclusionThe proposed design allows physicians, especially those in low resource setting, to estimate blood loss and deliver fluid accurately. This helps to reduce maternal mortality rate that may occur due to postpartum hemorrhage.

Indexed as

Diagnostic Techniques, Obstetrical and GynecologicalFemaleHemostatic TechniquesHumansPostpartum HemorrhagePregnancyBlood lossBlood pressureDiagnosisFluid deliveryMaternal mortalityPostpartum hemorrhage

Identifiers

PMID31771534
PMCPMC6878627
OpenAlexW2991621943

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.