Evidence map›Paper›PMID 31768641›Full record

ReviewCurrent atherosclerosis reports2019

The Current Literature on Bioabsorbable Stents: a Review.

Wally A Omar, Dharam J Kumbhani

Abstract readReview
PubMed Publisher
In one paragraph

Review in Current atherosclerosis reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 1 pooled it
5.7field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 1 synthesis or guideline pooled it, 65 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Review
  11. Review
  12. Review
  13. Article
  14. Applying Principles of Regenerative Medicine to Vascular Stent Development.Frontiers in bioengineering and biotechnology · 2022
    Review
  15. Review
  16. Article
  17. Modern Stents: Where Are We Going?Rambam Maimonides medical journal · 2020
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Wally A OmarDivision of Cardiology, University of Texas Southwestern Medical Center, 2001 Inwood Road Suite WC05.852, Dallas, TX, 75390-9254, USA.
Dharam J KumbhaniDivision of Cardiology, University of Texas Southwestern Medical Center, 2001 Inwood Road Suite WC05.852, Dallas, TX, 75390-9254, USA. dharam@post.harvard.edu.
The University of Texas Southwestern Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purpose of reviewThe purpose of this review is to explore the evolution of the coronary stent, from the advent of bare-metal stents, to the newest adopted technology of bioresorbable vascular scaffolds (BVS) used in bioresorbable stents. To date, there have been conflicting data regarding the safety and efficacy of BVS stents, especially when compared to current-generation drug-eluting stents (DES). This review will cover the data that exist regarding current BVS stents, as well as the active clinical trials for future iterations of BVS. RECENT

findingsThe ABSORB BVS, the most widely circulated stent of its class, was promised to decrease rates of stent thrombosis and target vessel revascularization. Several randomized control trials, however, found the opposite to be true, with the ABSORB BVS demonstrating higher rates of thrombosis, target vessel revascularization, and even target lesion myocardial infarctions when compared to current-generation DES. These data caused the product to be pulled from all markets, leaving the field with uncertainty as to the role of BVS in coronary interventions. Coronary stents have evolved significantly from 1977, when they were first introduced. The original bare-metal stent was later fitted with a drug-eluting polymer, to prevent restenosis and thrombosis over time. Subsequent iterations of the stent attempted to further mitigate that risk by replacing the durable polymer to one that is bioresorbable. The final step in this progression was to create a stent that was fully bioresorbable, which Abbott did with the creation of their ABSORB BVS stent. The product, however, was found to perform poorly when compared to current-generation drug-eluting stents, with several trials showing high rates of stent thrombosis (ST), late stent thrombosis (LST), target-lesion myocardial infarction, and target vessel revascularization. Observational studies of BVS stents have proposed several mechanisms for their thrombogenicity, including higher stent-strut profiles leading to turbulent flow, low radial strength leading to strut disruption, and a higher propensity for neoatherosclerosis. Given the failure of the first-generation BVS stent, but the lingering desire for fully bioresorbable scaffolds, various manufacturers have proposed their solutions with new stents. Until data from their clinical trials emerge, it remains unclear whether fully bioresorbable stents will play any role in coronary interventions.

Indexed as

Absorbable ImplantsDrug-Eluting StentsHumansMyocardial InfarctionPercutaneous Coronary InterventionPolylactic Acid-Polyglycolic Acid CopolymerProsthesis DesignThrombosisTime FactorsTreatment OutcomePolylactic Acid-Polyglycolic Acid CopolymerABSORBBioabsorbable polymerBioresorbable stentBioresorbable vascular scaffoldBiresorbable polymerDrug-eluting stentNeoatherosclerosisPercutaneous coronary intervention

Identifiers

PMID31768641
OpenAlexW2990836080

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.