Article in Scientific reports, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 24 citations in OpenAlex.
- Noninvasive malaria detection beyond blood sampling.Sensors & diagnostics · 2026Review
- Ultrasensitive ELISA for Accurate Detection ofOpen forum infectious diseases · 2025Article
- Highly Sensitive Readout Interface for Real-Time Differential Precision Measurements with Impedance Biosensors.Biosensors · 2023Article
- Urine and Saliva: Relevant Specimens for Malaria Diagnosis?Diagnostics (Basel, Switzerland) · 2022Review
- Review of Microdevices for Hemozoin-Based Malaria Detection.Biosensors · 2022Review
- PCR-assisted impedimetric biosensor for colibactin-encoding pks genomic island detection in E. coli samples.Analytical and bioanalytical chemistry · 2021Article
- Recent advances and challenges in electrochemical biosensors for emerging and re-emerging infectious diseases.Journal of electroanalytical chemistry (Lausanne, Switzerland) · 2020Review
- Recent Advances of Fluid Manipulation Technologies in Microfluidic Paper-Based Analytical Devices (μPADs) toward Multi-Step Assays.Micromachines · 2020Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Malaria elimination is a global public health priority. To fulfil the demands of elimination diagnostics, we have developed an interdigitated electrode sensor platform targeting the Plasmodium falciparum Histidine Rich Protein 2 (PfHRP2) protein in saliva samples. A protocol for frequency-specific PfHRP2 detection in phosphate buffered saline was developed, yielding a sensitivity of 2.5 pg/mL based on change in impedance magnitude of the sensor. This protocol was adapted and optimized for use in saliva with a sensitivity of 25 pg/mL based on change in resistance. Further validation demonstrated detection in saliva spiked with PfHRP2 from clinical isolates in 8 of 11 samples. With a turnaround time of ~2 hours, the label-free platform based on impedance sensors has the potential for miniaturization into a point-of-care diagnostic device for malaria elimination.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials