Evidence map›Paper›PMID 31766525›Full record

ArticleMicromachines2019

Investigation of the Young's Modulus and the Residual Stress of 4H-SiC Circular Membranes on 4H-SiC Substrates.

Jaweb Ben Messaoud, Jean-François Michaud, Dominique Certon, Massimo Camarda, Nicolò Piluso, Laurent Colin, Flavien Barcella, Daniel Alquier

Abstract read
In one paragraph

Article in Micromachines, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jaweb Ben MessaoudGREMAN UMR-CNRS 7347, Université de Tours, INSA Centre Val de Loire, 37071 Tours, France.
Jean-François MichaudGREMAN UMR-CNRS 7347, Université de Tours, INSA Centre Val de Loire, 37071 Tours, France.
Dominique CertonGREMAN UMR-CNRS 7347, Université de Tours, INSA Centre Val de Loire, 37071 Tours, France.
Massimo CamardaPaul Scherrer Institute, ODRA/116, 5232 Villigen, Switzerland.
Nicolò PilusoSTMicroelectronics, Stradale Primosole, 50, 95121 Catania, Italy.
Laurent ColinGREMAN UMR-CNRS 7347, Université de Tours, INSA Centre Val de Loire, 37071 Tours, France.
Flavien BarcellaGREMAN UMR-CNRS 7347, Université de Tours, INSA Centre Val de Loire, 37071 Tours, France.
Daniel AlquierGREMAN UMR-CNRS 7347, Université de Tours, INSA Centre Val de Loire, 37071 Tours, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The stress state is a crucial parameter for the design of innovative microelectromechanical systems based on silicon carbide (SiC) material. Hence, mechanical properties of such structures highly depend on the fabrication process. Despite significant progresses in thin-film growth and fabrication process, monitoring the strain of the suspended SiC thin-films is still challenging. However, 3C-SiC membranes on silicon (Si) substrates have been demonstrated, but due to the low quality of the SiC/Si heteroepitaxy, high levels of residual strains were always observed. In order to achieve promising self-standing films with low residual stress, an alternative micromachining technique based on electrochemical etching of high quality homoepitaxy 4H-SiC layers was evaluated. This work is dedicated to the determination of their mechanical properties and more specifically, to the characterization of a 4H-SiC freestanding film with a circular shape. An inverse problem method was implemented, where experimental results obtained from bulge test are fitted with theoretical static load-deflection curves of the stressed membrane. To assess data validity, the dynamic behavior of the membrane was also investigated: Experimentally, by means of laser Doppler vibrometry (LDV) and theoretically, by means of finite element computations. The two methods provided very similar results since one obtained a Young's modulus of 410 GPa and a residual stress value of 41 MPa from bulge test against 400 GPa and 30 MPa for the LDV analysis. The determined Young's modulus is in good agreement with literature values. Moreover, residual stress values demonstrate that the fabrication of low-stressed SiC films is achievable thanks to the micromachining process developed.

Indexed as

4H-SiCbulge testbulk micromachiningcircular membraneelectrochemical etchingFEMmechanical propertiesresidual stressvibrometryYoung’s modulus

Identifiers

PMID31766525
PMCPMC6953090

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.