ArticleSensors (Basel, Switzerland)2019
Magnetic Field Sensor Based on a Tri-Microfiber Coupler Ring in Magnetic Fluid and a Fiber Bragg Grating.
Article in Sensors (Basel, Switzerland), 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Temperature-Independent Sensor of the Magnetic Field Based on FBG and Terfenol-D.Nanomaterials (Basel, Switzerland) · 2023Article
- Ultrahigh-performance vector magnetic field sensor with wedge-shaped fiber tip based on surface plasmon resonance and magnetic fluid.Nanophotonics (Berlin, Germany) · 2022Article
- A Novel Airborne Molecular Contaminants Sensor Based on Sagnac Microfiber Structure.Sensors (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
In this paper we propose and investigate a novel magnetic field sensor based on a Tri-microfiber coupler combined with magnetic fluid and a fiber Bragg grating (FBG) in a ring. A sensitivity of 1306 pm/mT was experimentally demonstrated in the range of magnetic fields from 0 to 15 mT. The reflection peak in the output spectrum associated with the FBG serves as a reference point allowing to avoid ambiguity in determining the spectral shift induced by the magnetic field. Due to its high sensitivity at low magnetic fields, the proposed structure could be of high interest in low field biosensing applications that involve a magnetic field, such as magnetic manipulation or separation of biomolecules.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.